Age | Commit message (Collapse) | Author | Files | Lines |
|
This updates the needed patches for 4a.
The latest bump (version of 2019-01-17) has
make one of the previous patch obsolete (SIGSEGV
when closing the PCM), thus the patch has simply been
removed.
Also add a patch for having bluez-alsa request a name
on dbus.
BUG-AGL: SPEC-2126
Change-Id: I351b55e0d440f8f271ccb14a0d51111570659026
Signed-off-by: Thierry Bultel <thierry.bultel@iot.bzh>
|
|
This fixes the random crash at PCM close
Change-Id: I373e4b7e55d6d7d4c3be4a4a7a9f460c00758215
Signed-off-by: Thierry Bultel <thierry.bultel@iot.bzh>
|
|
This removes the deprecated PCM proxy hack, and brings mandatory
features for the softmixer.
This change applies on top of the latest bluez-alsa master of 2018-12-04
and brings 3 patches:
1) builds a shared library and links bluez-alsa and ioplug controls & pcm
to it.
2) func log by default
3) increase the number of max connections from clients (pcm & ctrls)
-----
Upstream status for the patches:
1) pending. Based on a submitted PR that is not clean enough and
that the maintainer does not want to take before at least 6 months
https://github.com/Arkq/bluez-alsa/pull/95
2) pending. Was submitted as part of the Ofono support in bluez-alsa,
but was not retained. See the original PR for Ofono for that.
3) pending. The maintainer is OK with this but wants to refactor the
client-server protocol in the coming months. In a private mail of
12/06/2018:
"Yes, you can increase this hardcoded limit as a temporary workaround.
I've put in there (and made it rather low) as a reminder, that clients
are stored in the list, which might not be optimal for larger number of
connected clients. In the future bluealsa will support audio mixing, so
connecting many clients to a single transport will be a common case. So,
I've thought about incorporating more efficient structure for storing
(in particular searching) connected client - something with log(n)
search complexity. Then, it might be worth to implement this container
to be dynamic with an upper capacity limit (which might be high, like
200-300 clients)."
Change-Id: Ia771613a7a83cc9ed6108399cdaacdeda603d39b
Signed-off-by: Thierry Bultel <thierry.bultel@iot.bzh>
|
|
This closes the transport connection when a null device is
specified.
Change-Id: I6d69c68a2ca91bd9fb3d7fdf51f470f243e76d5f
Signed-off-by: Thierry Bultel <thierry.bultel@iot.bzh>
|
|
This plugin always keeps the opened PCM in a consistent state
for the sound application, despite of bluez-alsa server or
device disconnection.
Bug: SPEC-1679
Change-Id: I0caaa6abe6fb9133b4d43479d452e542a04620c3
Signed-off-by: Ronan Le Martret <ronan.lemartret@iot.bzh>
Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh>
|