aboutsummaryrefslogtreecommitdiffstats
path: root/meta-rcar-gen2/recipes-kernel/linux/linux-renesas
diff options
context:
space:
mode:
authorManuel Bachmann <mbc@iot.bzh>2016-01-12 15:14:31 +0000
committerGerrit Code Review <gerrit@172.30.200.200>2016-01-13 15:25:21 +0000
commit900d5849ba787f9767800f463be58516b43a2f6c (patch)
tree64f0613b09a092e8020f460c785852b4e69187bc /meta-rcar-gen2/recipes-kernel/linux/linux-renesas
parent503179018b074828878568140be57b83f8790e14 (diff)
r-car m2: fix notification of groups with inode (SPEC-89)
This is a backport of the following kernel patch : https://git.kernel.org/cgit/linux/kernel/git/torvalds/ linux.git/commit/?id=8edc6e1 and fixes the following issue : https://jira.automotivelinux.org/browse/SPEC-89 (it fixes the reliability of using the "fa_notify" kernel API for filesystem notifications) Commit-Id: I968a52e72dc816a9f93640392b19ba2463216fe1 Signed-off-by: Manuel Bachmann <mbc@iot.bzh>
Diffstat (limited to 'meta-rcar-gen2/recipes-kernel/linux/linux-renesas')
-rw-r--r--meta-rcar-gen2/recipes-kernel/linux/linux-renesas/0022-fanotify-fix-notification-of-groups-with-inode-mount.patch206
1 files changed, 206 insertions, 0 deletions
diff --git a/meta-rcar-gen2/recipes-kernel/linux/linux-renesas/0022-fanotify-fix-notification-of-groups-with-inode-mount.patch b/meta-rcar-gen2/recipes-kernel/linux/linux-renesas/0022-fanotify-fix-notification-of-groups-with-inode-mount.patch
new file mode 100644
index 0000000..06723d7
--- /dev/null
+++ b/meta-rcar-gen2/recipes-kernel/linux/linux-renesas/0022-fanotify-fix-notification-of-groups-with-inode-mount.patch
@@ -0,0 +1,206 @@
+From 8edc6e1688fc8f02c8c1f53a2ec4928cb1055f4d Mon Sep 17 00:00:00 2001
+From: Jan Kara <jack@suse.cz>
+Date: Thu, 13 Nov 2014 15:19:33 -0800
+Subject: [PATCH] fanotify: fix notification of groups with inode & mount marks
+
+fsnotify() needs to merge inode and mount marks lists when notifying
+groups about events so that ignore masks from inode marks are reflected
+in mount mark notifications and groups are notified in proper order
+(according to priorities).
+
+Currently the sorting of the lists done by fsnotify_add_inode_mark() /
+fsnotify_add_vfsmount_mark() and fsnotify() differed which resulted
+ignore masks not being used in some cases.
+
+Fix the problem by always using the same comparison function when
+sorting / merging the mark lists.
+
+Thanks to Heinrich Schuchardt for improvements of my patch.
+
+Link: https://bugzilla.kernel.org/show_bug.cgi?id=87721
+Signed-off-by: Jan Kara <jack@suse.cz>
+Reported-by: Heinrich Schuchardt <xypron.glpk@gmx.de>
+Tested-by: Heinrich Schuchardt <xypron.glpk@gmx.de>
+Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
+Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
+---
+ fs/notify/fsnotify.c | 36 +++++++++++++++++++++---------------
+ fs/notify/fsnotify.h | 4 ++++
+ fs/notify/inode_mark.c | 8 +++-----
+ fs/notify/mark.c | 36 ++++++++++++++++++++++++++++++++++++
+ fs/notify/vfsmount_mark.c | 8 +++-----
+ 5 files changed, 67 insertions(+), 25 deletions(-)
+
+diff --git a/fs/notify/fsnotify.c b/fs/notify/fsnotify.c
+index 9d3e9c5..89326ac 100644
+--- a/fs/notify/fsnotify.c
++++ b/fs/notify/fsnotify.c
+@@ -229,8 +229,16 @@ int fsnotify(struct inode *to_tell, __u32 mask, void *data, int data_is,
+ &fsnotify_mark_srcu);
+ }
+
++ /*
++ * We need to merge inode & vfsmount mark lists so that inode mark
++ * ignore masks are properly reflected for mount mark notifications.
++ * That's why this traversal is so complicated...
++ */
+ while (inode_node || vfsmount_node) {
+- inode_group = vfsmount_group = NULL;
++ inode_group = NULL;
++ inode_mark = NULL;
++ vfsmount_group = NULL;
++ vfsmount_mark = NULL;
+
+ if (inode_node) {
+ inode_mark = hlist_entry(srcu_dereference(inode_node, &fsnotify_mark_srcu),
+@@ -244,21 +252,19 @@ int fsnotify(struct inode *to_tell, __u32 mask, void *data, int data_is,
+ vfsmount_group = vfsmount_mark->group;
+ }
+
+- if (inode_group > vfsmount_group) {
+- /* handle inode */
+- ret = send_to_group(to_tell, inode_mark, NULL, mask, data,
+- data_is, cookie, file_name, &event);
+- /* we didn't use the vfsmount_mark */
+- vfsmount_group = NULL;
+- } else if (vfsmount_group > inode_group) {
+- ret = send_to_group(to_tell, NULL, vfsmount_mark, mask, data,
+- data_is, cookie, file_name, &event);
+- inode_group = NULL;
+- } else {
+- ret = send_to_group(to_tell, inode_mark, vfsmount_mark,
+- mask, data, data_is, cookie, file_name,
+- &event);
++ if (inode_group && vfsmount_group) {
++ int cmp = fsnotify_compare_groups(inode_group,
++ vfsmount_group);
++ if (cmp > 0) {
++ inode_group = NULL;
++ inode_mark = NULL;
++ } else if (cmp < 0) {
++ vfsmount_group = NULL;
++ vfsmount_mark = NULL;
++ }
+ }
++ ret = send_to_group(to_tell, inode_mark, vfsmount_mark, mask,
++ data, data_is, cookie, file_name, &event);
+
+ if (ret && (mask & ALL_FSNOTIFY_PERM_EVENTS))
+ goto out;
+diff --git a/fs/notify/fsnotify.h b/fs/notify/fsnotify.h
+index 9c0898c..3b68b0a 100644
+--- a/fs/notify/fsnotify.h
++++ b/fs/notify/fsnotify.h
+@@ -12,6 +12,10 @@ extern void fsnotify_flush_notify(struct fsnotify_group *group);
+ /* protects reads of inode and vfsmount marks list */
+ extern struct srcu_struct fsnotify_mark_srcu;
+
++/* compare two groups for sorting of marks lists */
++extern int fsnotify_compare_groups(struct fsnotify_group *a,
++ struct fsnotify_group *b);
++
+ extern void fsnotify_set_inode_mark_mask_locked(struct fsnotify_mark *fsn_mark,
+ __u32 mask);
+ /* add a mark to an inode */
+diff --git a/fs/notify/inode_mark.c b/fs/notify/inode_mark.c
+index e849714..dfbf544 100644
+--- a/fs/notify/inode_mark.c
++++ b/fs/notify/inode_mark.c
+@@ -194,6 +194,7 @@ int fsnotify_add_inode_mark(struct fsnotify_mark *mark,
+ {
+ struct fsnotify_mark *lmark, *last = NULL;
+ int ret = 0;
++ int cmp;
+
+ mark->flags |= FSNOTIFY_MARK_FLAG_INODE;
+
+@@ -219,11 +220,8 @@ int fsnotify_add_inode_mark(struct fsnotify_mark *mark,
+ goto out;
+ }
+
+- if (mark->group->priority < lmark->group->priority)
+- continue;
+-
+- if ((mark->group->priority == lmark->group->priority) &&
+- (mark->group < lmark->group))
++ cmp = fsnotify_compare_groups(lmark->group, mark->group);
++ if (cmp < 0)
+ continue;
+
+ hlist_add_before_rcu(&mark->i.i_list, &lmark->i.i_list);
+diff --git a/fs/notify/mark.c b/fs/notify/mark.c
+index d90deaa..34c38fa 100644
+--- a/fs/notify/mark.c
++++ b/fs/notify/mark.c
+@@ -210,6 +210,42 @@ void fsnotify_set_mark_ignored_mask_locked(struct fsnotify_mark *mark, __u32 mas
+ }
+
+ /*
++ * Sorting function for lists of fsnotify marks.
++ *
++ * Fanotify supports different notification classes (reflected as priority of
++ * notification group). Events shall be passed to notification groups in
++ * decreasing priority order. To achieve this marks in notification lists for
++ * inodes and vfsmounts are sorted so that priorities of corresponding groups
++ * are descending.
++ *
++ * Furthermore correct handling of the ignore mask requires processing inode
++ * and vfsmount marks of each group together. Using the group address as
++ * further sort criterion provides a unique sorting order and thus we can
++ * merge inode and vfsmount lists of marks in linear time and find groups
++ * present in both lists.
++ *
++ * A return value of 1 signifies that b has priority over a.
++ * A return value of 0 signifies that the two marks have to be handled together.
++ * A return value of -1 signifies that a has priority over b.
++ */
++int fsnotify_compare_groups(struct fsnotify_group *a, struct fsnotify_group *b)
++{
++ if (a == b)
++ return 0;
++ if (!a)
++ return 1;
++ if (!b)
++ return -1;
++ if (a->priority < b->priority)
++ return 1;
++ if (a->priority > b->priority)
++ return -1;
++ if (a < b)
++ return 1;
++ return -1;
++}
++
++/*
+ * Attach an initialized mark to a given group and fs object.
+ * These marks may be used for the fsnotify backend to determine which
+ * event types should be delivered to which group.
+diff --git a/fs/notify/vfsmount_mark.c b/fs/notify/vfsmount_mark.c
+index ac851e8..faefa72 100644
+--- a/fs/notify/vfsmount_mark.c
++++ b/fs/notify/vfsmount_mark.c
+@@ -153,6 +153,7 @@ int fsnotify_add_vfsmount_mark(struct fsnotify_mark *mark,
+ struct mount *m = real_mount(mnt);
+ struct fsnotify_mark *lmark, *last = NULL;
+ int ret = 0;
++ int cmp;
+
+ mark->flags |= FSNOTIFY_MARK_FLAG_VFSMOUNT;
+
+@@ -178,11 +179,8 @@ int fsnotify_add_vfsmount_mark(struct fsnotify_mark *mark,
+ goto out;
+ }
+
+- if (mark->group->priority < lmark->group->priority)
+- continue;
+-
+- if ((mark->group->priority == lmark->group->priority) &&
+- (mark->group < lmark->group))
++ cmp = fsnotify_compare_groups(lmark->group, mark->group);
++ if (cmp < 0)
+ continue;
+
+ hlist_add_before_rcu(&mark->m.m_list, &lmark->m.m_list);
+--
+1.8.3.1
+