aboutsummaryrefslogtreecommitdiffstats
AgeCommit message (Collapse)AuthorFilesLines
2017-03-16Rename class and 1:1 map to JSON description fileRomain Forlot7-55/+73
Added decoder and callback member that will be set by generator and taken at submission to be used later, storing them into an active diagnostic request instance, when response CAN message comes in. Change-Id: I9ded05de3bb28ec55e4e007d72d0e1924141a6a6 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Make available decoding OBD2 messages method to be use as callback.Romain Forlot4-19/+22
Change the method to static 'cause it will be call from outside of the class. Change-Id: I88dcd845559fac7892cd489cd6e8198c143ee2a8 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Simplification of checking Diagnostic response.Romain Forlot3-26/+17
A CAN message will be considered as a Diagnostic response when its arbitration ID is between standardized 0x7E8 and 0x7EF. Checking which request belong to that response will done in later methods Change-Id: I7a093edf44b62a4552b90fe3d8935f94dc677cf4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve memory allocation about Signal states.Romain Forlot4-12/+12
Returning to Signal states map avoiding hole in vector allocation as we did not know how many state a Signal can takes. So a map may be a better choice Will see. Change-Id: Ie3ccdbd31296c5c0ebaefc109e75f2e0cde03756 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Revert accessing CAN device with a map indexing on dev nameRomain Forlot13-42/+73
Main reason for that behavior revert is because of generator that rely on CAN device name and so we have point on these object by specify the device name. Instead of shared pointer between objects, instead binding is based on device name. With a device name you can get the shared pointer on it using new static method from can_bus_t object. Change-Id: I331e0ad8d03c88a15c697d12a9fce3699b0cd962 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Uniformization between get_name() method of signals.Romain Forlot1-2/+2
can_signal_t and active_diagnostic_message return name with prefix using this method. If you need without it then use get_generic_name. Change-Id: I6b153eb20214049c10619d39fcc65c8641a9e32f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Littles comments improvmentsRomain Forlot1-2/+2
Change-Id: Idcc7e5b4dedad8e39eb829b25502d7dea3e5b29a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Change way to check prefix of signals name.Romain Forlot2-2/+5
Change-Id: I9a0726ab41c4801e7a5305731ce78ddd03aff9e1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve shims_logger function to get full details.Romain Forlot1-3/+8
Change-Id: I752db65cb3fbca4d33b932f3a0c597adfaf79903 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Get recurring requests works.Romain Forlot1-38/+33
Implements event_loop logic. Change-Id: Ia5ac32820a0421bbcb69d8b0dd3bea2b7b582444 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Simplification of diagnostic manager. Delete uneeded vectorRomain Forlot2-51/+22
Control size manually, don't rely on STL container. Change-Id: Iede2f9b233c5b8a6dc77c9b146ffc92da8e7a989 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Return period without unit conversion.Romain Forlot1-3/+1
If conversion must be made then make it at the call not upstream. Change-Id: Ief6dee40355c7b39b5e27d0ba3dc02717fadf43b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Search signals against name not generic_name. It's madeRomain Forlot2-3/+3
to get able to get difference between classic CAN messages and diagnostic messages based on name signals prefix. Change-Id: I696facc58f38150e0457d519dcabffba750a8db3 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Less control before process the CAN message.Romain Forlot1-6/+5
Change-Id: I341d29d217b2a92652e9985d8c93829e0211bddc Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Implement regular event launching using systemd event loopRomain Forlot3-21/+49
Regular events is made launch a timerfd event from binder event loop and then in the event handler, reschedule next launch in the future based upon the signal frequency. Change-Id: I0b1e84eb2135474f4bcc5ee256ba513eea4035a6 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve logging messages and change string conversion to charRomain Forlot1-5/+5
for the needed case. They were some inversion between needs of char variable and string. Fix: don't add diagnostic request if it is an unsubscrition operation. Change-Id: I1acedc413e7c5fe57da86812faf8d3c83d13c405 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Move diagnostic requests scheduling to diagnostic managerRomain Forlot2-8/+22
while adding the request. It is more logic to make that here than in the subscription operation. Change-Id: I19b29bc11c5fb6e5828a0bf189fac1333b0199ed Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: Initialization and entries flowRomain Forlot1-8/+11
between diagnostic manager vector. Change-Id: I9ea196b5dc5bbf2dd4509080a9a58d754fa42b6c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Enabling recurrent check of diagnostic requests.Romain Forlot1-0/+1
Change-Id: I16aff65c5ce22faac78e3f1d99ce7b33941c007c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve Doxygen comments and formating.Romain Forlot12-268/+281
Change-Id: Ia39e78aca00a49c7cee5e42d26ba1ef2b49d3709 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve: DEBUG messages.Romain Forlot2-2/+2
Change-Id: Ib52f22e7bc5bc5d14edbb31ad6006caee23c4098 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: return before initialization of diagnostic manager.Romain Forlot1-4/+2
Change-Id: I8485dec1ec5bb5dbea7edf4d9ac3a7d800b567b2 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Make decoder systematic use of openxc-utils to buildRomain Forlot1-12/+5
its objects. We don't want random initialization on boolean value of openxc_DynamicField (has_string, has_numeric...) else we have a risk that the final decoded and convert into json object will not be the good one. Change-Id: If4d69e6ace615fd8e097ba9a04e5482c82b9a7db Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Implement signals states decoder and change mapRomain Forlot4-23/+26
to a vector. Change-Id: I185724f2966fecac6659d401751da56d2886ed9d Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Search into generic_name as well as name + prefix, butRomain Forlot3-4/+8
always register generic_name into subscribed_signals. It will be the output on event and make easier to find the subscribed signals into the map without prefix. Change-Id: Iaf0060bedb54003b0c77121afd2bd35d832dba25 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Adding/Fix classes constructors to make them correspondRomain Forlot7-40/+70
to the ones generated. Change-Id: I6b0b778f59ac52fe66e36a327f60ae58550ac271 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Separation of classes in the same file.Romain Forlot5-66/+88
Change-Id: Ifc690cc27028659ffaf5a8a2e9caabc1e0718fd4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Move member from obd2_signals_t class toRomain Forlot6-85/+53
active_diagnostic_request_t (adr)class. It's more logical to have them here as call about incoming diagnostic CAN messages are made against adr class not obd2_signal_t that it's a subset of diagnostic messages. It's made to handle obd2 requests as well as normal UDS diagnostic request for constructor proprietary diagnostic signals. Change-Id: I96c714640d6ecfa25dfc9942974057c1797eb0e1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Get decoding diagnostic request from decoding thread of can_bus_tRomain Forlot8-51/+224
Decoding divided in 2 subfunctions dedicated to decode either pure CAN messages or diagnostic (obd2) message. About now, a diagnostic request has a name then it will be pushed on the event_queue as a SimpleMessage. Without name full details of diagnostic response will be pushed as diagnostic response. This behavior follows the one from OpenXC. Change-Id: I255f3f6487fa9511ea47c74606014995a7b0f720 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Change the way to check signal type making prefix_Romain Forlot5-12/+14
attribute as static with a static class method which will check that the beginning of string argument matches the prefix. Change-Id: Idb129c7179391da61447996560957b2791aa9383 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Reordering class method.Romain Forlot1-17/+17
Change-Id: I61cca1117a987280383538a0b0e307429bee4fc3 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Adding instruction to use the binding.Romain Forlot1-5/+83
Miss an example with an UI or CLI interface. Change-Id: Ib26fe53f16fbdeb79f79fee15fce20ce3342d210 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: set to microsecond frequency check of diag requestRomain Forlot2-6/+3
Change-Id: I871ff68afd7f398d4c7d3a550c8926c1f7e67cb3 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16fix: test for opened CAN socket.Romain Forlot1-5/+5
Change-Id: If9e3a0511c7ccc703817069a56bd38d7e64ebb09 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Keep subscription to signal simplier without doublingRomain Forlot1-45/+8
functions dedicated to different signal type as they aren't so much difference between. Change-Id: Ic2090c2d755136183dfc08a9b84efa3388d3747b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Default value about thread state set at false.Romain Forlot3-13/+4
Change-Id: I1934aa4d9a9d945a32d8e369cf0f36b1e06d3f34 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Change configuration location into an etc directory.Romain Forlot2-3/+3
Change-Id: I4648f2eb203f37844bfb8deb2527f93b4852e82c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: wrong location to make the increment because we useRomain Forlot1-1/+1
the device after so... This was total crap ! Change-Id: I9bb43c3f75c613a5927f342b3c574871c0eb65bb Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix CMakeLists file to get isotp correctly linked and addingRomain Forlot1-3/+3
missing libssytemd Change-Id: Id065ff16a7f582ba1cf88423c75bf4c11fb026d9 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Missing include header and code reordering and cleaning.Romain Forlot2-5/+5
Change-Id: I37b2b2b439bb72d2230d606b9ddd52c3eb08ea8f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Change method returned value. Needed with send_request()Romain Forlot2-10/+7
method to retrieve the active_diagnostic_request. Change-Id: Icfba704e40be211021dc81ec18fa3602d736afdb Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Implemente way to send diagnostic request when subscribed.Romain Forlot10-8/+167
When subscribed, the signal is added to recurring request list of diagnostic manager and an event is added to the systemd event loop with timer set using frequency parameter from the requested signal. Change-Id: I4d604c498047d7744c090b7f03fce0f2b427fd01 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Use of signals prefix to be able to distinguish type ofRomain Forlot2-5/+11
messages to be processed. For now, processing prefix is hardcoded but idea is to process them dynamically if possible. To be studied. Change-Id: Iac0c96228fc5f53e3c637e54350188ff3de6d57f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Make diagnostic manager initialization processus.Romain Forlot7-46/+58
It is initiliazed with by default the first CAN bus device in the CAN bus device list from CAN bus manager. The object is instancied at configuration_t object first invokation and after all CAN buses has been initialized then the diag manager is initialized too. Change-Id: I4894f2c62f575676c34efec3608b97de8c5326e1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Adding diagnostic_messages from diagnostic.json fileRomain Forlot1-1/+26
from openxc example. The json is now a mixed example between CAN messages and diagnostic messages. Change-Id: I94ed5ac7d48e1fb1bb42b3df00d953d45ee0fc7d Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16We doesn't modify member once getted, we can use const returnRomain Forlot5-13/+37
and const method. Change-Id: I0f7465af74b1c9a546af45a0d1eea33c93537e0c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Manage prefix on CAN and OBD2 prefix. Searching signalsRomain Forlot7-50/+55
is made on generic_name (without prefix) and returned vector of string is filled with name with prefix. Then you can process on them based upon their name differently. OBD2 signals will generated recurring request on diagnostic manager and decoding will not be handled the same way too. Change-Id: I2c5239ef49661941a0a748debe0bd536b2954b3a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Remove uneeded define as it was already present in uds.hRomain Forlot2-5/+0
Change-Id: I04091b35ec072e9c19f5af0689ed89db0d5070bd Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Instead of a global pointer, config is now a Singleton.Romain Forlot7-18/+20
Change-Id: I0cfc34f330c531ba5f070542a1cb723be4bcc70a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Also initialize the id_ renamed address_ member. This memberRomain Forlot3-7/+6
is mapped to the address node from json Change-Id: Ied13067723552c2396337a9f85fe5e1418ba8caf Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>