Age | Commit message (Collapse) | Author | Files | Lines |
|
No more binder interface needed to use logging macros and
others stuff like make_event or any other calls
Change-Id: Iaee60697373bc8a0e67518e924b36b5389533e68
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I9f032cc232e77ce73e889a1656f1ad86cfdec774
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Creation of an object which old the subscription context
(filter, signal) : low_can_subscription_t
- Move socket from can_signal_t to this new object.
- Adding a member to can_message_t to transport subscription_id to be able to
retrieve it with all the context through running.
Change-Id: I87be8cd6c3c93a81040357920d8c081a316800c3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Several style errors and mistakes mostly on constructor and passing arguments
as ref.
Change-Id: I2ca921d6aa70b9074392bb7779ade35bebf7bd8d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
and store into frequency_clock_t.
Change-Id: If209070298bd9df49297fdcbed554770e1bc0e4a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idd600a47960850cd4afc553fdb79f5c57f93f64b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
In addition to signal last_values, now message last value is also set.
Change-Id: I87c2be3e4e68073d7708b2ddf681889576337410
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As well as handling reading signals BCM socket using systemd event loop.
Change-Id: I1e121635ec5db489b2bcb88a3101e716bf8883d5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change include statement to refer the correct new path to the files.
Also change CMakeLists.txt.
Change-Id: I66a0bccab02e9fce10072a275a6580d61b4ddfbe
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ie876614266fd2e7089754a8f917d25d316de4c98
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
Fix: wrong call since renaming of function to more generic name
Change-Id: I2adebb855bc815ba6ab14a1002b17d9c9fb293fd
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Added for all log messages function name at beginning using __FUNCTION__ macro.
Change-Id: Ia0f476ca81b9f79c6d49b425c0520894c59797ea
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Each projects, binder and generator, has to be compiled separatly.
CAN-binder will host high and low level binding
CAN-config-generator only the generator used for low level binding.
build.sh script just launch both build in their respective dir.
Change-Id: Ic77932660fcca507b23a631d4e4e790f608880ae
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|