summaryrefslogtreecommitdiffstats
path: root/CAN-binder/low-can-binding/diagnostic
AgeCommit message (Collapse)AuthorFilesLines
2017-05-19Format renamingRomain Forlot2-7/+6
Change-Id: I40c28f584c444ef806c2adcc55d443a145abb0d2 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Remove can-bus-dev following RAW->BCM sockets migrationRomain Forlot1-2/+0
No needs to get RAW socket for now, so can_bus_dev_t class is useless and now removed from project. Change-Id: I37b3e187ef28ba393beae7a99da4f422f74a298e Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Fix: be able to receive new response from OBD2 requests.Romain Forlot1-1/+1
Change-Id: Iab309e313f63beb4b56bc824ece1b3a5e42ae508 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Fix: CAN message transmitted filled of zero.Romain Forlot1-0/+1
can_dlc field was set to 0 and is evaluated so BCM assumes there is no data to transmit. It is mandatory to set it. Change-Id: I1e29ff4248a49212d3fee22c3a0cc77f5b699fd7 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Fix: listening on broadcast CAN ID.Romain Forlot1-1/+1
Wrong test about CAN ID, it isn't the response ID that is passed as argument but the broadcast. Little mistake... Change-Id: I2622c23356802c3108dbf8e6ede07456294834ee Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Implement canceling with BCM socket leads to close it.Romain Forlot1-17/+1
Change-Id: Ibcc1419caba7e1b04dbe652a6c60c393f14a8145 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Adding also diagnostic request to systemd event loopRomain Forlot2-4/+21
As for CAN signal, monitoring diagnostic request messages is now handled by systemD io event loop. Socket reading is common for all OBD2 signals and handled by the diagnostic manager. systemd callback function lies in binding callback which in turns call read_socket method of diagnostic manager. Processing is little bit different from classic CAN messages so it is a separate callback function. Lot of cleaning to do now... Change-Id: I4d2ada0beb5d3348736dfdf3c56a7cb875a1c6c7 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19There is no more need having pointer on socket deviceRomain Forlot1-1/+5
Return bus name string. Change-Id: I0e7f4171c3d1052cb6425cd5b93e5a593d7d277f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Simplify testing name size...Romain Forlot1-1/+1
Change-Id: I3daa11b329f2e38efba5a52c2106bddd3b759f86 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19Reworking diagnostic manager to use BCM sockets.Romain Forlot4-100/+125
Use 2 sockets: - TX sockets on active_diagnostic_request class as we need X sockets using the same CAN ID "7DF" with different timing settings - RX socket on diagnostic_manager object as we need to read the same CAN ID and process them the same way, there isn't so much need to split them. Change-Id: I7338fd751a033a1d0e8912ee554e2c72c43961c3 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-19FormatRomain Forlot2-9/+27
Change-Id: Idc49593fdc1a039c6a03626115e4156a629e4e65 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-05-04Follow the moving binding and configuration files.Romain Forlot3-3/+3
Change include statement to refer the correct new path to the files. Also change CMakeLists.txt. Change-Id: I66a0bccab02e9fce10072a275a6580d61b4ddfbe Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-04-24Misc: Cleanup, typo, formating and comments update.Romain Forlot2-7/+3
Change-Id: Icac565b9a3a80dc05a1a3470a35e223c8c564347 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-04-22Improve logging messagesRomain Forlot1-19/+19
Added for all log messages function name at beginning using __FUNCTION__ macro. Change-Id: Ia0f476ca81b9f79c6d49b425c0520894c59797ea Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-04-21Move all signals search functions into new signals_manager_t objectRomain Forlot1-3/+4
Create a class from signals lookup and find standalone function and gather all find function into it. There is now only 1 function to find either CAN signals or diagnostic messages, results are returned using an ad-hoc struct containing vector of one or the other type pointers. This object also hold subscribed_signals map with events, so this class is a singleton. Change-Id: I3584c6a91201e6904edc6aeac0abfa1785bdeccc Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-04-14Change directory architecture to use 2 separated projects.Romain Forlot6-0/+1220
Each projects, binder and generator, has to be compiled separatly. CAN-binder will host high and low level binding CAN-config-generator only the generator used for low level binding. build.sh script just launch both build in their respective dir. Change-Id: Ic77932660fcca507b23a631d4e4e790f608880ae Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>