Age | Commit message (Collapse) | Author | Files | Lines |
|
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
No more binder interface needed to use logging macros and
others stuff like make_event or any other calls
Change-Id: Iaee60697373bc8a0e67518e924b36b5389533e68
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I9f032cc232e77ce73e889a1656f1ad86cfdec774
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I026111942b4b8486b46f56d5fc92fcebde4dc91f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Subscription index map is the socket ID which implies the following:
- All diagnostic messages subscriptions are stored into a vector
holding diagnostic_message and there is 1 socket for all like the
diag manager did.
- Reworked workflow to open a BCM socket and adding an RX filter more flexible.
- Separated methods to handle on_no_clients event.
- Cleaning diagnostic manager code to remove all unneeded stuff now.
- Embed diagnostic response in VehicleMessage decoded message to be able
transmits the PID in event push thread. This is needed by to correctly handle case
when there is no clients subscribed to an AFB event. Else we can't find
the diagnostic message to remove from low_can_subscription vector.
Change-Id: Iab13fd556cda3c69827bcd67f3a23a03cb6a2cf2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
can_signal_t use socket number but has for OBD2 diagnostic request
there is only 1 socket to listen all response then we use PID has key
to find the subscription later on the processing.
Change-Id: I5f0554e1a4ac43e1046d9b7b7f9bb00d3a753562
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Creation of an object which old the subscription context
(filter, signal) : low_can_subscription_t
- Move socket from can_signal_t to this new object.
- Adding a member to can_message_t to transport subscription_id to be able to
retrieve it with all the context through running.
Change-Id: I87be8cd6c3c93a81040357920d8c081a316800c3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
and store into frequency_clock_t.
Change-Id: If209070298bd9df49297fdcbed554770e1bc0e4a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Needed because we use systemd event loop that recommend that.
Change-Id: Ia3faf35fe80a973f7a7b1c81f6a8adf96705394b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We always read the same object so how to fill it is the job of specialized class
not a generic method can do that.
Change-Id: Ia262871cec6b7ed3341eb314d5ed6641b8da61e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now derivated class use constructor from base class and we don't destroy
socket when a socket object is over since it may be copied before. So closing
them is in charge of dev, well me...
Change-Id: I0440119017a3e56bb83d0194a6908dc3e2b8f745
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I91155eda22a172efc88f72243c260480a2d1d4ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Copy constructors are allowed since socket will never be closed during binding
runs.
Change-Id: Ie33e4b7e885d45e1ffeb980400df00ae2a97e45d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use to initialize raw, bcm and later isotp socket. Now we should have,
1 BCM socket by signal to make filter on them. 1 raw socket by devices is kept
to use diagnostic manager as is.
Change-Id: Icb2daddf67039479f72bc487d53971adc9aba638
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|