Age | Commit message (Collapse) | Author | Files | Lines |
|
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
No more binder interface needed to use logging macros and
others stuff like make_event or any other calls
Change-Id: Iaee60697373bc8a0e67518e924b36b5389533e68
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I9f032cc232e77ce73e889a1656f1ad86cfdec774
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I026111942b4b8486b46f56d5fc92fcebde4dc91f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I682cacca1af53f898ac4c428f823562c50e7cce4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Subscription index map is the socket ID which implies the following:
- All diagnostic messages subscriptions are stored into a vector
holding diagnostic_message and there is 1 socket for all like the
diag manager did.
- Reworked workflow to open a BCM socket and adding an RX filter more flexible.
- Separated methods to handle on_no_clients event.
- Cleaning diagnostic manager code to remove all unneeded stuff now.
- Embed diagnostic response in VehicleMessage decoded message to be able
transmits the PID in event push thread. This is needed by to correctly handle case
when there is no clients subscribed to an AFB event. Else we can't find
the diagnostic message to remove from low_can_subscription vector.
Change-Id: Iab13fd556cda3c69827bcd67f3a23a03cb6a2cf2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Id0f088f030c0a23b4347c4886a3d756538cbb651
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8974827340e3faf60a511900cbdcf117ce43fb53
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As socket is back to only movable, only one copy of a socket
can be present at a time, so when the object is destroyed we have
to close the socket too.
Change-Id: Id64bb53919ce7c24476c26ba9a8520affa3f6273
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I54eab7da7e5819f633a5612abe46d44550068aab
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ibbd48a1c0fe0e7567cbf3f5f1c6919e542883924
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Following change from configuration_t to application_t some
variable name doesn't correspond now : conf -> app
Change-Id: I56c3a83113777a43af9024a9bc9b53f705b60b0f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
can_signal_t use socket number but has for OBD2 diagnostic request
there is only 1 socket to listen all response then we use PID has key
to find the subscription later on the processing.
Change-Id: I5f0554e1a4ac43e1046d9b7b7f9bb00d3a753562
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Set afb_event into subscription object then there is no more
std::pair used t access it, better use a method from
low_can_subscription_t class
Change-Id: Ic0772d97c18ca8899821cf3ce175166bbe0be660
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8401030ece94b5e397b6d2b71b29ff4e435d1486
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I08aba32f1273c7be305ceacf121e42fddfca173e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Creation of an object which old the subscription context
(filter, signal) : low_can_subscription_t
- Move socket from can_signal_t to this new object.
- Adding a member to can_message_t to transport subscription_id to be able to
retrieve it with all the context through running.
Change-Id: I87be8cd6c3c93a81040357920d8c081a316800c3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
These structures doesn't not have to change after.
Change-Id: I0cc83136c7ee4e5f5cd9c04bf717814e141f98c5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: If81e2a18c0beec392a98f8b835c7a5d154360500
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
It is more accurate to name it application because all its
members aren't modifiable at runtime (without talking of last_value_
member and few others).
Change-Id: Ica0d33dfd9c26cfdea019c2f41ed07777fb36d39
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Implement socket copy assignment operator on socketcan base class.
Change-Id: I75a2d3b96275b7ab83372d74ff7fe0a0b0535dc7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Several style errors and mistakes mostly on constructor and passing arguments
as ref.
Change-Id: I2ca921d6aa70b9074392bb7779ade35bebf7bd8d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Store CAN device map without prefixed section name and add methods to get
the mapped device name.
Change-Id: I03ebc175c67b2251016863b0d69a45a816a81d25
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
and store into frequency_clock_t.
Change-Id: If209070298bd9df49297fdcbed554770e1bc0e4a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As can_message_definitions got the exact same name but the one from can_message_set
is an aggregate of all can_message_definition. So it is clearer using a different
name.
Change-Id: Ieb9e4d3291f3dc460eb352d8b8fe5a7cf479e687
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia43f9c0edf09ff9a1c009f198bdad10a6b44b249
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use a vector of string pair that map index on vector and pair map logical bus
name with linux device name.
Change-Id: I627e6f715f7466d835d8729e21d9e4198111c1fb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I174c546afb6b21df431e0a61677292d43af8f0ca
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I287e445c6f1c372a852752911d032a70654aa082
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Multiplication was a very specific needs for diagnostic manager when using
systemd event loop timer. Now it is the right period that is calculated and
multiplication is done into the right place. Cleaner.
Change-Id: Ie3dffe8daa0fa9bd9bde408e62a8d7a06a333a25
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Else we got infinite value if 0 and negative value doesn't make sense here.
Change-Id: Id65f0aa94cae32f1fea2c5c80028e328e6958a13
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As there will be more bcm socket and more need to set its timer values.
May be there is a better method to separate integer and decimal parts from
a float value.
Change-Id: I0cd992dfde5fe8257b17b5b610482f5f5e09aa8c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Return bus name string.
Change-Id: I0e7f4171c3d1052cb6425cd5b93e5a593d7d277f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib31483663a90c8dad129f59372e1ced3a79c7403
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idc49593fdc1a039c6a03626115e4156a629e4e65
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Vector of shared_ptr is made to shared ownership about object around project.
This is the default returned value by getter methods when lookup and manipulating
them.
Change-Id: Id37947bb5994b629f4bf3faecc5ffac81c55e1e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ibcd71f585246172c191b67b45e3b2763f7722958
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Needed because we use systemd event loop that recommend that.
Change-Id: Ia3faf35fe80a973f7a7b1c81f6a8adf96705394b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We always read the same object so how to fill it is the job of specialized class
not a generic method can do that.
Change-Id: Ia262871cec6b7ed3341eb314d5ed6641b8da61e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I89d227e48add0c7fc8a4ca577023995b269e6f13
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now derivated class use constructor from base class and we don't destroy
socket when a socket object is over since it may be copied before. So closing
them is in charge of dev, well me...
Change-Id: I0440119017a3e56bb83d0194a6908dc3e2b8f745
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I91155eda22a172efc88f72243c260480a2d1d4ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As well as handling reading signals BCM socket using systemd event loop.
Change-Id: I1e121635ec5db489b2bcb88a3101e716bf8883d5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change include statement to refer the correct new path to the files.
Also change CMakeLists.txt.
Change-Id: I66a0bccab02e9fce10072a275a6580d61b4ddfbe
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Copy constructors are allowed since socket will never be closed during binding
runs.
Change-Id: Ie33e4b7e885d45e1ffeb980400df00ae2a97e45d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use to initialize raw, bcm and later isotp socket. Now we should have,
1 BCM socket by signal to make filter on them. 1 raw socket by devices is kept
to use diagnostic manager as is.
Change-Id: Icb2daddf67039479f72bc487d53971adc9aba638
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1c0e04e38fec92dee167720c3128a7493d4cf9b2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1878e26a519a8e2708cfbfd59c6dd95e968d4028
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ie63c962cfe191cca71c5927eafa72a3ab69befac
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Just allowing message with 1 frame avoiding to handle dynamic sized array...
This close the door for multiplexed msg for now... Let's see later and move on
Change-Id: I3626d4b6634b3f119826603e64713d63e994918e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|