Age | Commit message (Collapse) | Author | Files | Lines |
|
Change-Id: Ia43f9c0edf09ff9a1c009f198bdad10a6b44b249
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use a vector of string pair that map index on vector and pair map logical bus
name with linux device name.
Change-Id: I627e6f715f7466d835d8729e21d9e4198111c1fb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I174c546afb6b21df431e0a61677292d43af8f0ca
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I287e445c6f1c372a852752911d032a70654aa082
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Multiplication was a very specific needs for diagnostic manager when using
systemd event loop timer. Now it is the right period that is calculated and
multiplication is done into the right place. Cleaner.
Change-Id: Ie3dffe8daa0fa9bd9bde408e62a8d7a06a333a25
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Else we got infinite value if 0 and negative value doesn't make sense here.
Change-Id: Id65f0aa94cae32f1fea2c5c80028e328e6958a13
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As there will be more bcm socket and more need to set its timer values.
May be there is a better method to separate integer and decimal parts from
a float value.
Change-Id: I0cd992dfde5fe8257b17b5b610482f5f5e09aa8c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Return bus name string.
Change-Id: I0e7f4171c3d1052cb6425cd5b93e5a593d7d277f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib31483663a90c8dad129f59372e1ced3a79c7403
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idc49593fdc1a039c6a03626115e4156a629e4e65
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Vector of shared_ptr is made to shared ownership about object around project.
This is the default returned value by getter methods when lookup and manipulating
them.
Change-Id: Id37947bb5994b629f4bf3faecc5ffac81c55e1e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ibcd71f585246172c191b67b45e3b2763f7722958
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Needed because we use systemd event loop that recommend that.
Change-Id: Ia3faf35fe80a973f7a7b1c81f6a8adf96705394b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We always read the same object so how to fill it is the job of specialized class
not a generic method can do that.
Change-Id: Ia262871cec6b7ed3341eb314d5ed6641b8da61e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I89d227e48add0c7fc8a4ca577023995b269e6f13
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now derivated class use constructor from base class and we don't destroy
socket when a socket object is over since it may be copied before. So closing
them is in charge of dev, well me...
Change-Id: I0440119017a3e56bb83d0194a6908dc3e2b8f745
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I91155eda22a172efc88f72243c260480a2d1d4ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As well as handling reading signals BCM socket using systemd event loop.
Change-Id: I1e121635ec5db489b2bcb88a3101e716bf8883d5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change include statement to refer the correct new path to the files.
Also change CMakeLists.txt.
Change-Id: I66a0bccab02e9fce10072a275a6580d61b4ddfbe
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Copy constructors are allowed since socket will never be closed during binding
runs.
Change-Id: Ie33e4b7e885d45e1ffeb980400df00ae2a97e45d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use to initialize raw, bcm and later isotp socket. Now we should have,
1 BCM socket by signal to make filter on them. 1 raw socket by devices is kept
to use diagnostic manager as is.
Change-Id: Icb2daddf67039479f72bc487d53971adc9aba638
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1c0e04e38fec92dee167720c3128a7493d4cf9b2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1878e26a519a8e2708cfbfd59c6dd95e968d4028
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ie63c962cfe191cca71c5927eafa72a3ab69befac
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Just allowing message with 1 frame avoiding to handle dynamic sized array...
This close the door for multiplexed msg for now... Let's see later and move on
Change-Id: I3626d4b6634b3f119826603e64713d63e994918e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use AFB log system
Change-Id: I5aa727ce7f9db5b6f18df5957f31f37d9af88d20
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Wrong signature using const argument with the obj receiving the read
Change-Id: I0c5b8a3c974f0bd140823f8ce88aa2cbd451e543
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I33b32418980059b701d2af5b165af536f42d0252
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I0ec6d74e9adb791f8bef44f76c74be8365cdf037
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Will read a can_message_t object from socket
Change-Id: Ibe3561f9d7bbf4e41b6fd81fa4672bae1c14aca5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Created special struct to handle bcm messages with can_frame and canfd_frame.
We can now just send both of them seamlessly.
Change-Id: Ia84e9cf2ab1dd0716cb09f6bb342a208e54f8e06
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Either returning signal with search against generic_name either against name,
not both.
Change-Id: I597718d04c99d098973442b4174e735e813c9b94
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Also use CAN FD frames by default.
Change-Id: I5bad10e537653b1a96c2e3012d38dde8627d3caa
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Wrong condition testing making connect and bind happens.
Change-Id: Ic75a74d044e9763fdf42e50f7643b26ffaf5d76d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Added for all log messages function name at beginning using __FUNCTION__ macro.
Change-Id: Ia0f476ca81b9f79c6d49b425c0520894c59797ea
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Create a class from signals lookup and find standalone function and gather all
find function into it. There is now only 1 function to find either CAN signals
or diagnostic messages, results are returned using an ad-hoc struct containing
vector of one or the other type pointers.
This object also hold subscribed_signals map with events, so this class is a singleton.
Change-Id: I3584c6a91201e6904edc6aeac0abfa1785bdeccc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Move all legacy opening RAW CAN socket operation to socket class. Each operations
on a CAN socket has to be simple and made by the socket class.
Simple BCM socket open operation is implemented.
Future will be to open specialized BCM CAN sockets on demand.
Change-Id: If285b97afb9871245ab1f13cd9f0401fbd9adf95
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ie47171ba633274c31a5e0965919232e91ac74adb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I6f90c87c164bc6ba70ee0889668f54f4972a8610
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib67fab1ecd5085e089769e7905cd5ebcd28b9c7c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Much simpler but also a bit limitated. Could be change easily in futur if needed
Change-Id: I06f03f093c9206007e3d0c1e86a35d60111be5f8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Instead of specifying a JSON configuration file with CAN devices name, it uses
a mapping configuration file that map a high level device names to a real low level names.
File path is to be specified into the generated source code which is /etc/dev-mapping.conf
for now.
Configuration file uses INI file format and is parsed using inih library cpp wrapper.
Change-Id: Ibde104e76cd78a6cc86f6eec4f66c274b7567d43
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Each projects, binder and generator, has to be compiled separatly.
CAN-binder will host high and low level binding
CAN-config-generator only the generator used for low level binding.
build.sh script just launch both build in their respective dir.
Change-Id: Ic77932660fcca507b23a631d4e4e790f608880ae
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|