Age | Commit message (Collapse) | Author | Files | Lines |
|
New redundant function creation to mutualize code between two operations.
Change-Id: I8516c2c6d2f0c1d5cf89244ea23b831530e84a5f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idc49593fdc1a039c6a03626115e4156a629e4e65
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I038677d688c64e87ae86dd2af245f87f5c40e317
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Vector of shared_ptr is made to shared ownership about object around project.
This is the default returned value by getter methods when lookup and manipulating
them.
Change-Id: Id37947bb5994b629f4bf3faecc5ffac81c55e1e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now we respect JSON description file, which is can_message_set contains
can_message_definition which contains can_signals.
Diagnostic messages aren't processed for now.
Change-Id: I94aaf5eded14dd84395bd4fd749df58dee5f533e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ibcd71f585246172c191b67b45e3b2763f7722958
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I23b862e748e13e7ba69743c8a9d3abb0be36c4bc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
So use const value
Change-Id: I81f9a4766d71116e2f3a2af8785b1bd1c69e2c20
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib84c365207e32f71fc4cb7e350f99d147317fa08
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Needed because we use systemd event loop that recommend that.
Change-Id: Ia3faf35fe80a973f7a7b1c81f6a8adf96705394b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We always read the same object so how to fill it is the job of specialized class
not a generic method can do that.
Change-Id: Ia262871cec6b7ed3341eb314d5ed6641b8da61e6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
In addition to signal last_values, now message last value is also set.
Change-Id: I87c2be3e4e68073d7708b2ddf681889576337410
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
And reset can_reader to can_bus_dev_t like the old behavior because BCM sockets
has been implemented at signals level not device.
Change-Id: I715a19ff65bf9d7231c73b66c1ee95b3f41f8ed0
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Even if the frame read is wrong doesn't mean that socket is compromise only
that communication on CAN bus is difficult, maybe temporary. On en EPOLL err
code, or hangup, just close and restart the socket and reset the filter.
Change-Id: I61f146fd269bb2524f09e1f2ed89d93e83166136
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1c080f961f62a6816b0c36e960ae1ecbeb7fa00d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I89d227e48add0c7fc8a4ca577023995b269e6f13
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now derivated class use constructor from base class and we don't destroy
socket when a socket object is over since it may be copied before. So closing
them is in charge of dev, well me...
Change-Id: I0440119017a3e56bb83d0194a6908dc3e2b8f745
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ibec47106f8510e92a017fc08aeb2eeaeef2884e5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Move create_rx_filter to can_signals and adding all accessories needed to works.
Change-Id: I3636fe82ce5c2e43a4992b66ce89440ff709004a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I91155eda22a172efc88f72243c260480a2d1d4ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As well as handling reading signals BCM socket using systemd event loop.
Change-Id: I1e121635ec5db489b2bcb88a3101e716bf8883d5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib24f8c2000f78f5f6fea3126e52f34570e4eee18
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change include statement to refer the correct new path to the files.
Also change CMakeLists.txt.
Change-Id: I66a0bccab02e9fce10072a275a6580d61b4ddfbe
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
https://gerrit.automotivelinux.org/gerrit/#/admin/projects/apps/app-templates
Change-Id: I42eff75b790b70047e1b91b963edf458084881c9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Copy constructors are allowed since socket will never be closed during binding
runs.
Change-Id: Ie33e4b7e885d45e1ffeb980400df00ae2a97e45d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Icedbe5b8c420b0fb77eb331577e11c35c4597d80
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Iaf68d463e9df4d6dda2a8508adf5395041d2ff7f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8cb170613c003bbdb39240eb809b8cefcad6cb35
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I804abe6eb0965b54fb93bc8da2b1e1665b99476d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use to initialize raw, bcm and later isotp socket. Now we should have,
1 BCM socket by signal to make filter on them. 1 raw socket by devices is kept
to use diagnostic manager as is.
Change-Id: Icb2daddf67039479f72bc487d53971adc9aba638
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1c0e04e38fec92dee167720c3128a7493d4cf9b2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now libraries are cleanly included and built.
Change-Id: Iaa85639578b55b2da8357bc438426403e2cca8de
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Following the new CMake template from https://gerrit.automotivelinux.org/gerrit/apps/app-templates
these CMake files use helpers macros from macros.cmake and project configuration config.cmake.
Change-Id: I2297b6ad6c65cd763d1870d5b62564e8795f4317
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1878e26a519a8e2708cfbfd59c6dd95e968d4028
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I4e6d1ce805d7e7fef66eac177f10fe5f163d79b5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I88a1ef090b7ce40c833c5780f5a481876ff7ea09
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ie63c962cfe191cca71c5927eafa72a3ab69befac
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Just allowing message with 1 frame avoiding to handle dynamic sized array...
This close the door for multiplexed msg for now... Let's see later and move on
Change-Id: I3626d4b6634b3f119826603e64713d63e994918e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ibc820dea7efbc2d7a50671ce66804217c6707d56
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: If12617ae086d7023ff619799833cd1d4fd0fd413
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Adding a boolean parameter similarly of existing function to know if we would send
the event.
Change-Id: I03ee17f656065e556fd2b72b160b140852b68dcc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ie876614266fd2e7089754a8f917d25d316de4c98
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
Fix: wrong call since renaming of function to more generic name
Change-Id: I2adebb855bc815ba6ab14a1002b17d9c9fb293fd
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I4e72db1e7b7bc31d7446a4903972687f1ec9d71c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use AFB log system
Change-Id: I5aa727ce7f9db5b6f18df5957f31f37d9af88d20
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Wrong signature using const argument with the obj receiving the read
Change-Id: I0c5b8a3c974f0bd140823f8ce88aa2cbd451e543
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I4f1d5cd489011675cf55914647b57c7332dec1b9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Can't be 0 subscription so success if greater than 0
Change-Id: Ie4395dbabe4ed85fe939ebdfa9de87e210fa55bc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I33b32418980059b701d2af5b165af536f42d0252
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I7462b5d0144987293376dab719d1cf4fa41406f2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now reading thread hold in can_bus_t object instead of can_bus_dev_t and reading
happens using select().
Change-Id: Ib8cc68c4484679168519f3c0fa485fedd1616c74
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|