summaryrefslogtreecommitdiffstats
path: root/examples
AgeCommit message (Collapse)AuthorFilesLines
2019-08-30Add feature ISO TP (multi frames and peer to peer)Arthur Guyader2-1/+255
This commit adds the ISO TP feature. The ISO TP protocol allows to communicate between two ECU. The protocol allows multi packets management. Bug-AGL : SPEC-2779 Change-Id: Ic222615b547f28e926930e6c1dea2c0265055afd Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Replace all enum types with masksArthur Guyader4-182/+1172
This commit allows to change all enum types by masks. Now to implement new protocol you don't need to add more attribute in class. All can be contained in the flags field. Bug-AGL : SPEC-2779 Change-Id: I814d0052139be5d5efefc9ff1b4b558f46b85e90 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-12Update examples and can_samplesArthur Guyader13-280/+2380
Update of examples for new features (is_fd,is_extended,is_j1939). Bug-AGL: SPEC-2386 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Change-Id: I8c3afbafdde4f5818d73c0e71a3b7e47fb7d8fc6
2019-06-27Updating application-generated.cpp.Romain Forlot9-944/+2391
This commit updates differents application-generated.cpp files with the low-can generator updated with j1939. This commit adds the description of j1939 messages. Bug-AGL: SPEC-2386 Change-Id: I798a7da34c1be3526fec6bc3e424a6b88eaf46ff Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-11-22Use newly generated cpp file with default encodersRomain Forlot6-1/+6
Change-Id: I7bf15568a16e0c84c4f590ca07eba48ecd34157f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-07-27Updated examples files and default configurationRomain Forlot6-43/+46
Let use the new decoder's function and set some hvac signals as writable to be able to test this feature. Change-Id: I27e1c2be069b8bb55ed931ad1fb629aa2d4e5b86 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-05-24Fixing typos made in commentsydimitrov2-2/+2
This change set fixes the comments made by previous contributors v2: Fix line end v3: Making changes to comments as suggested by reviewers v4: Removing trailing spaces v5: Clearing small typo in low-can-cb.cpp on line 142 Change-Id: Ifbcfc3b2d131d1db0b25e472955b21e98cc09f45 Signed-off-by: ydimitrov <y.dimitrov.14@gmail.com>
2018-04-17Add saving of diagnostic messages informationJonathan Aillet4-66/+132
Add saving of diagnostic messages receive state, last value, and timestamp associated to it. Add methods to get/set these information. Add initialisation for added atributes. Add boolean to set receive state at initialisation. Generate all 'diagnostic-message.cpp' containing diagnostic messages to add receive state initialisation. Bug-AGL: SPEC-1347 Change-Id: Iee82ca3b5f79fd267717ae074d5456b8cbc1c377 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2017-07-21Examples reorganizationRomain Forlot12-652/+2341
Separated by protocols and created signals from reversed engineered signals. Meld all used signals into an "agl-vcar" folder to be used as default. Change-Id: I27f7bc227a6fcea3db6672819e6a4d7bbf09863b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-07-21FormatRomain Forlot1-10/+10
Change-Id: I036befbfb38b01d046d35a1364c28e0835dcbd41 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-07-21Include HVAC and meld with Toyota examples one.Romain Forlot1-93/+321
Change-Id: Ia55dbcd7cabcd38d532a239cb00f8480a095bda2 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-07-21Cleaning and renaming.Romain Forlot1-5/+5
Change-Id: I24b78e3d41124650da286a50297f1c51410c2c6a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-07-21Example regenerationRomain Forlot2-169/+270
Change-Id: Iab06c4aebcc4172ae831c8fda2d3986315fb94c2 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-06-20Separation Generator to a dedicated repoRomain Forlot5-0/+943
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-04-14Change directory architecture to use 2 separated projects.Romain Forlot5-910/+0
Each projects, binder and generator, has to be compiled separatly. CAN-binder will host high and low level binding CAN-config-generator only the generator used for low level binding. build.sh script just launch both build in their respective dir. Change-Id: Ic77932660fcca507b23a631d4e4e790f608880ae Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-04-11Adding K2L CAN signals to toyota examples.Romain Forlot1-2/+61
Change-Id: I147c439217dcc1f0709bd55f670ff1893cc77262 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-31Added some new OBD2 signalsRomain Forlot1-0/+14
Change-Id: Ied85c5acef8e9ce215c01166180fc07d5c5b0dcd Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-20Update toyota exampleRomain Forlot2-22/+22
Change-Id: Ied4f715b486a2d4ef2b5ba4d49bbc339f95bffad Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-18Improve Toyota examples.Romain Forlot2-19/+91
Generate a new version of the configuration generated for Toyota Auris 2010. Remove the one from src directory. It has to be paste prior to build the binding once generated. Change-Id: I0b8e5415df0d0fade70dfa193ad45770c6db38dd Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-17added toyota's exemple.Loïc Collignon2-0/+451
Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>
2017-03-17moved exemples files.Loïc Collignon3-0/+314
Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>