Age | Commit message (Collapse) | Author | Files | Lines |
|
Add a flag to CAN message definitions which set the message as using FD
protocol if true.
Use a new generated file with the new FD flag field on the message
definitions.
Change BCM socket "struct" using an union to store the CAN frames either
using the FD struct or the classic non FD struct. A BCM socket can only
one frame type once configured.
Use as much as possible the "struct canfd_frame" in the binding and only
make a difference before writing or reading the socket. From a memory
point of view both struct are identical and only the last member differ
and could hold more data with messages of 64 bytes long. So the
canfd_frame is compatible with the can_frame and can be differentiated
by a flag set in the can_id member.
Remove now unused code processing can_frame.
Keep the diagnostic manager using the classic CAN frame.
Set the maximum number of frames that a BCM socket can handle to 257.
Bug-AGL: SPEC-1980
Change-Id: Ifcc041281ea6745fc25cbd384743761f4446f489
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I7bf15568a16e0c84c4f590ca07eba48ecd34157f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Let use the new decoder's function and set some hvac signals
as writable to be able to test this feature.
Change-Id: I27e1c2be069b8bb55ed931ad1fb629aa2d4e5b86
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Create first tests to be used with afb-test binding
The test binding is now found using pkg-config command.
Change-Id: Ib1cd08236b6b8fab93ccb67ac613a9c83908d12e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Add saving of diagnostic messages receive state, last value,
and timestamp associated to it.
Add methods to get/set these information.
Add initialisation for added atributes.
Add boolean to set receive state at initialisation.
Generate all 'diagnostic-message.cpp' containing diagnostic messages
to add receive state initialisation.
Bug-AGL: SPEC-1347
Change-Id: Iee82ca3b5f79fd267717ae074d5456b8cbc1c377
Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
|
|
Separated by protocols and created signals from reversed
engineered signals.
Meld all used signals into an "agl-vcar" folder to be used as
default.
Change-Id: I27f7bc227a6fcea3db6672819e6a4d7bbf09863b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I24b78e3d41124650da286a50297f1c51410c2c6a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|