summaryrefslogtreecommitdiffstats
path: root/low-can-binding/binding/application-generated.cpp
AgeCommit message (Collapse)AuthorFilesLines
2019-08-30Add feature ISO TP (multi frames and peer to peer)Arthur Guyader1-0/+182
This commit adds the ISO TP feature. The ISO TP protocol allows to communicate between two ECU. The protocol allows multi packets management. Bug-AGL : SPEC-2779 Change-Id: Ic222615b547f28e926930e6c1dea2c0265055afd Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Replace all enum types with masksArthur Guyader1-26/+24
This commit allows to change all enum types by masks. Now to implement new protocol you don't need to add more attribute in class. All can be contained in the flags field. Bug-AGL : SPEC-2779 Change-Id: I814d0052139be5d5efefc9ff1b4b558f46b85e90 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-12Update examples and can_samplesArthur Guyader1-48/+1017
Update of examples for new features (is_fd,is_extended,is_j1939). Bug-AGL: SPEC-2386 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Change-Id: I8c3afbafdde4f5818d73c0e71a3b7e47fb7d8fc6
2019-06-27Updating application-generated.cpp.Romain Forlot1-514/+396
This commit updates differents application-generated.cpp files with the low-can generator updated with j1939. This commit adds the description of j1939 messages. Bug-AGL: SPEC-2386 Change-Id: I798a7da34c1be3526fec6bc3e424a6b88eaf46ff Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Rename some of the classes removing can- prefixRomain Forlot1-51/+51
This commit renames files and classes : - can_message_definition_t -> message_definition_t - can_message_set_t -> message_set_t - can_signals_t -> signals_t This prepares the implementation of j1939 protocol. Bug-AGL: SPEC-2386 Change-Id: Ie3ee4f25c236c861b92eb12a56fa03a5a9afffbb Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Use shared_ptr to set message_set parentRomain Forlot1-1/+1
Better to use shared_ptr instead of raw pointer if possible. Bug-AGL: SPEC-2386 Change-Id: Id853d8ac6cddd1e53edd84e3bf27b0f1f5d92d4b Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-02-06Add fake can data for dashboardzheng_wenlong1-0/+156
Add these fake can data. We want to modify dashboard, let is show more information. accelerator.pedal.position steering.wheel.angle transmission.gearinfo transmission.mode turnsignal.status lightstatus.brake parking.brake.status Change-Id: Ief9f29684f3463af0d0f98f1dd213b633d1889bb Signed-off-by: zheng_wenlong <wenlong_zheng@nexty-ele.com>
2018-12-14CAN FD implementationRomain Forlot1-6/+42
Add a flag to CAN message definitions which set the message as using FD protocol if true. Use a new generated file with the new FD flag field on the message definitions. Change BCM socket "struct" using an union to store the CAN frames either using the FD struct or the classic non FD struct. A BCM socket can only one frame type once configured. Use as much as possible the "struct canfd_frame" in the binding and only make a difference before writing or reading the socket. From a memory point of view both struct are identical and only the last member differ and could hold more data with messages of 64 bytes long. So the canfd_frame is compatible with the can_frame and can be differentiated by a flag set in the can_id member. Remove now unused code processing can_frame. Keep the diagnostic manager using the classic CAN frame. Set the maximum number of frames that a BCM socket can handle to 257. Bug-AGL: SPEC-1980 Change-Id: Ifcc041281ea6745fc25cbd384743761f4446f489 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-11-22Use newly generated cpp file with default encodersRomain Forlot1-0/+1
Change-Id: I7bf15568a16e0c84c4f590ca07eba48ecd34157f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-07-27Updated examples files and default configurationRomain Forlot1-6/+6
Let use the new decoder's function and set some hvac signals as writable to be able to test this feature. Change-Id: I27e1c2be069b8bb55ed931ad1fb629aa2d4e5b86 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-07-09Add testssandbox/excale/wipRomain Forlot1-2/+2
Create first tests to be used with afb-test binding The test binding is now found using pkg-config command. Change-Id: Ib1cd08236b6b8fab93ccb67ac613a9c83908d12e Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-04-17Add saving of diagnostic messages informationJonathan Aillet1-21/+42
Add saving of diagnostic messages receive state, last value, and timestamp associated to it. Add methods to get/set these information. Add initialisation for added atributes. Add boolean to set receive state at initialisation. Generate all 'diagnostic-message.cpp' containing diagnostic messages to add receive state initialisation. Bug-AGL: SPEC-1347 Change-Id: Iee82ca3b5f79fd267717ae074d5456b8cbc1c377 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2017-07-21Examples reorganizationRomain Forlot1-1/+77
Separated by protocols and created signals from reversed engineered signals. Meld all used signals into an "agl-vcar" folder to be used as default. Change-Id: I27f7bc227a6fcea3db6672819e6a4d7bbf09863b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-07-21Cleaning and renaming.Romain Forlot1-11/+11
Change-Id: I24b78e3d41124650da286a50297f1c51410c2c6a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-06-20Separation Generator to a dedicated repoRomain Forlot1-0/+564
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>