summaryrefslogtreecommitdiffstats
path: root/low-can-binding/binding/low-can-cb.cpp
AgeCommit message (Collapse)AuthorFilesLines
2020-01-09format: remove uneeded brackets.Romain Forlot1-31/+0
Change-Id: I0689d62e32b9b60059adc2d4be78fa3b2581441c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09j1939: Follow updates of the kernelArthur GUYADER1-0/+3
This commit patch j1939 feature after the update of the kernel from linux-can-next to mainline. Now promisc option removes filter of the bind. The option is now a parameter in the event_filter. The feature recv_own isn't available, you can't receive on the same socket an emit frame from you. Not a big problem because receive and send method use two different sockets in the implementation. Change-Id: I5ac410177c1512090827870300b8aa1679477b84 Signed-off-by: Arthur GUYADER <arthur.guyader@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09diag_mngr: No diagnostic msg if no diagnostic_busRomain Forlot1-1/+1
Change-Id: I840fc6cc7e9cfd171b03cac508fedb8ece4b976d Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09low-can-cb: Little optiRomain Forlot1-4/+2
Change-Id: I6f3e84700563fc60e643d770365c98342214bedd Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09diag-mngr: Fix sending and change initRomain Forlot1-17/+16
This commit fix the wrong bcm ival1 value set because the struct hasn't been initialized so it use a wrong value that can not be handled by the socket. Initialize diagnotstic manager depending on JSON configuration file This avoid to request engine_speed signal when there isn't any diagnostic_bus configured in the JSON file. Change-Id: I98145a6e20c29a644c856d818f104c6bd8069f9f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09init: Improve error message when not finding config fileRomain Forlot1-1/+1
Bug-AGL: SPEC-2988 Change-Id: I9a9dec6e577881bbd784bcae1d17ddb244d94599 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09low-can: Fix init failing when using without J1939Romain Forlot1-1/+1
Return variable was initialized to 1 instead of 0 and without using J1939 this variable isn't reaffected and so the final test fails. Bug-AGL: SPEC-2386 Change-Id: I53b7cd757b3b344d66ab18ba9795284105cbcfcc Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09low-can-cb: improve readabilityRomain Forlot1-11/+6
Just make thing more readable by define variables at the beginning of functions. And directly assign them if possible. Also improve format using the same format than in the rest of the project. Bug-AGL: SPEC-2932 Change-Id: I5cc7685b80734d0eb43a29fc06b2a8434f3469fa Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09can-bus: Use configuration from JSON fileRomain Forlot1-1/+7
Use configuration from JSON file instead of the old INI file. Now all configuration files lies within the binding tree. Bug-AGL: SPEC-2988 Change-Id: Id986d19751db958ad5cf3b7f2b2c5443d4ceb062 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09fix: missing include to find find_if functionRomain Forlot1-0/+1
Change-Id: I099b951011442ffaebf75a319236a39553999a41 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09message: More explicit define about CAN protocols.Romain Forlot1-6/+6
Change a bit CAN binding define about used protocol. There was a mistake about BCM define which isn't a protocol at all but a maner to filter and retrieve CAN message through SocketCAN. Also FD_FRAME was using the same name than SocketCAN which isn't a good idea, better to distinguis both of them. Bug-AGL: SPEC-2988 Change-Id: I255fa03029c7d5f90a33448e5e7692d8c249279b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09low-can-cb: Mark the end of the CtlSections arrayRomain Forlot1-1/+4
Bug-AGL: SPEC-2988 Change-Id: I433f4f699f3234fc07fcd909cd6b77b84e447ad7 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09low-can-cb: Retrieve application from external controller dataRomain Forlot1-5/+4
Bug-AGL: SPEC-2988 Change-Id: Iaa55b00539b1435b00fe076918d5eda5eeb5db30 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09binding: add preinit function to load the configRomain Forlot1-69/+84
Make as the others bindings using controller and load its configuration file at preinit step. diagnostic-manager: Change way to initialize the diag bus This was kind of hardcoded and now, it is initialized by a configuration key of the controller configuration JSON file. Bug-AGL: SPEC-2988 Change-Id: I344c1982893e47600a0b8cd03542de8069a42d24 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-09All: Make format coherent with the whole projectRomain Forlot1-15/+15
Add a space after a comma Change some aligments Bug-AGL: SPEC-2988 Change-Id: I5069120f4bbb33742bb4990e2e1f391ec8d5eeb6 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-08j1939: don't process signals using same busRomain Forlot1-6/+8
Bug-AGL: SPEC-2991 Change-Id: I8733a35e4f9cb3d0f2fce818b55a010fec19dc66 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-08all: Format one line 'if' or 'for' statement.Romain Forlot1-75/+18
Bug-AGL: SPEC-2988 Change-Id: Ic3b9670a2ce9e982220c54f3632f690ee4eea686 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2020-01-08subscription: Optimizing opening socketsRomain Forlot1-11/+11
Also review some aligment and make more space between bool ops Bug-AGL: SPEC-2988 Change-Id: I613f294a630caf48eea7bb0c7b9c36b07cbacfbf Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-08-30Remove file socketcan-j1939 that was not removed beforeArthur Guyader1-0/+1
Bug-AGL : SPEC-2780 Change-Id: I4ddf9389faffebe0334b0004b69bb7336277c29d Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Add some typedef to reduce the size of the linesArthur Guyader1-11/+11
Bug-AGL : SPEC-2779 Change-Id: Iebcf7492133cd7789d301593ff999b24ae10a054 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Change vector to list to allow to remove signal.Arthur Guyader1-8/+24
This commit allows to remove signals. We need that because subscription to an iso tp message needs to be individual. Bug-AGL : SPEC-2779 Change-Id: I1d6410ebfc8ea82d33addf1bb828d9cd810b006a Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Add feature ISO TP (multi frames and peer to peer)Arthur Guyader1-35/+81
This commit adds the ISO TP feature. The ISO TP protocol allows to communicate between two ECU. The protocol allows multi packets management. Bug-AGL : SPEC-2779 Change-Id: Ic222615b547f28e926930e6c1dea2c0265055afd Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Replace all enum types with masksArthur Guyader1-20/+20
This commit allows to change all enum types by masks. Now to implement new protocol you don't need to add more attribute in class. All can be contained in the flags field. Bug-AGL : SPEC-2779 Change-Id: I814d0052139be5d5efefc9ff1b4b558f46b85e90 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Only defined signals can be writtenArthur Guyader1-26/+59
This commits ensure that only known signals could be written using the binding's api. Before that you was able to wrote raw frames on the CAN bus without any checks if this was a known signals to the binding. Bug-AGL : SPEC-2779 Change-Id: Ied6680e926f2a9c221fee31d8fb78d2d39c41132 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-30Update function rx_filter_can for multi frame prevision.Arthur Guyader1-1/+1
This commit updates the functions rx_filter_can to anticipate the development of the multi-frame. Bug-AGL : SPEC-2779 Change-Id: I5f67cf84e5d3e47c75c588f8776ead92eb6c3c8e Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-29Update function to encode and decode messageArthur Guyader1-1/+1
This commit update encoder and decoder files. This new implementation allows to manage larger signals. Bug-AGL : SPEC-2779 Change-Id: Iec6dfbd279863aa8b8e8f9e3ce951f0c8aa80dae Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-29Uniform indentation with tabulationArthur Guyader1-17/+17
Bug-AGL : SPEC-2779 Change-Id: I834221ae1a04fdb188062ce1b7251e648c4845de Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
2019-08-13Fix: only one subscription could be madeRomain Forlot1-2/+1
Only one subscription could be made and then only one subscriber could receive associated events. As the relationship between events and subscriber is not 1-1 but 1-N, so this was the mistake. Now 1 event is created for N subscriber where before there was 1 event for 1 subscriber and subsequent subscribers could not receive same events than the ones already subscribed. Bug-AGL: SPEC-2726 Change-Id: I4e4a80ac9f9b6b4c6b006108ee55f355a7c1e377 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-08-12Integrate the J1939 features : address claiming and write.Arthur Guyader1-12/+80
This commit allows to write J1939 messages and add the management of the address claiming. Bug-AGL: SPEC-2386 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Change-Id: I1bb95a7ba6f6ebe463319c3972d9d46897181d51
2019-08-12Add feature to build messages and fix some functionsArthur Guyader1-29/+134
Allows to build a message (J1939,BCM) with a signal and a value. Bug-AGL: SPEC-2386 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Change-Id: Iadca13a927ff83f713f39da441c88356695a1285
2019-06-27Minor improvementsRomain Forlot1-2/+2
- Remove now unused forward declaration of active_diagnostic_request_t - Factorize calling the signals_manager at binding initialization. - retab... Bug-AGL: SPEC-2386 Change-Id: I418fddd80ef8b856c198dc697760a6edf0918012 Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Small fixes (include and pointer)Romain Forlot1-1/+1
Bug-AGL: SPEC-2386 Change-Id: I3a622b9d236283aff479f187451cd86557a9aba7 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Add the possibility to subscribe an id or a pgnArthur Guyader1-21/+86
The commit allows at the time of subscription to do: -> low-can subscribe {"id": 48} -> low-can subscribe {"pgn": 61442} The generation of event_filter has been extracted in a separate function. Bug-AGL: SPEC-2386 Change-Id: I592e668c63be448562b27c81fcdc111cd34f3676 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Rename some of the classes removing can- prefixRomain Forlot1-14/+14
This commit renames files and classes : - can_message_definition_t -> message_definition_t - can_message_set_t -> message_set_t - can_signals_t -> signals_t This prepares the implementation of j1939 protocol. Bug-AGL: SPEC-2386 Change-Id: Ie3ee4f25c236c861b92eb12a56fa03a5a9afffbb Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Change can_message_t class usage for new j1939Romain Forlot1-5/+5
This commit transforms the class can_message_t as the base class and creates two derived classes: j1939_message_t and can_message_t. Bug-AGL: SPEC-2386 Change-Id: I6d3afd8e4f5abff2cd0ec4e9910bd52a2893de76 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Use subscription's sockets as shared_ptrRomain Forlot1-9/+13
This change is made to leverage C++ to read and write the different socket classes depending on CAN protocol used. Bug-AGL: SPEC-2386 Change-Id: I5e25e271fc82e9627f836aeb43b2af5ef25db83a Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Implement a new socket type CAN for j1939 protocolArthur Guyader1-4/+4
This commit implements a new socket class for the j1939 protocol and prepares the bases classes by modifying the write and read methods. Bug-AGL: SPEC-2386 Change-Id: I16ba493418a4bb37a0262b61a2a2629be6ab5051 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-12-14Smalls improvementsRomain Forlot1-1/+1
- Improve robustness reading a BCM socket Adding checks on system calls and remove the initialization of the struct that will hold the received message, not so much needed in that case. - More accurate log message at subscription/unsubscription step whether this is a FD CAN messages or not and if this a subscription or an unsubscription that is requested. - Initialize the full struct of vehicle message to avoid memory warning about conditionnal jump based on uninitialized bytes. - Memleak: Free raw pointer on active diagnostic requests Change-Id: I4bbf4d851c0fa1efdb6fa6034fac3d1dcafa1a73 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-12-14Simpler handling of binding subscriptionsRomain Forlot1-46/+39
Don't use a child class for subscription, only use one because there isn't other different subscriptions type to be implemented about now and if so then we could split again. Remove functions no longer useful and move afb events and afb subscriptions part to low-can-subscription Change-Id: Ie3e4255961ac557465098cdb48730098a950461a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-12-14Cleaning the code for now unused functionsRomain Forlot1-3/+1
Also formating and retabulating some comments Change-Id: I95eda93e78fabeb336ca02e94307364954ab2318 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-12-14CAN FD implementationRomain Forlot1-33/+30
Add a flag to CAN message definitions which set the message as using FD protocol if true. Use a new generated file with the new FD flag field on the message definitions. Change BCM socket "struct" using an union to store the CAN frames either using the FD struct or the classic non FD struct. A BCM socket can only one frame type once configured. Use as much as possible the "struct canfd_frame" in the binding and only make a difference before writing or reading the socket. From a memory point of view both struct are identical and only the last member differ and could hold more data with messages of 64 bytes long. So the canfd_frame is compatible with the can_frame and can be differentiated by a flag set in the can_id member. Remove now unused code processing can_frame. Keep the diagnostic manager using the classic CAN frame. Set the maximum number of frames that a BCM socket can handle to 257. Bug-AGL: SPEC-1980 Change-Id: Ifcc041281ea6745fc25cbd384743761f4446f489 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-11-22Rework writing CAN message on CAN buses.Romain Forlot1-79/+64
- Adds the possibility to use a custom encoder function - Use of wrap_json functions instead of raw json-c functions - Return the error informations in the request return. - Reduce conditionnal imbrication Bug-AGL: SPEC-1965 Change-Id: I766b3cf3e6998d03a8a2f3e51117e8b26fc9b56f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-10-15Migration to binding v3Romain Forlot1-43/+40
Change-Id: I0bcccb15200064bd7d83edbf06c1e7202069189a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-05-25Merge "Fixing typos made in comments"flounder_5.99.1flounder/5.99.15.99.1Jan-Simon Moeller1-9/+9
2018-05-24Fixing typos made in commentsydimitrov1-9/+9
This change set fixes the comments made by previous contributors v2: Fix line end v3: Making changes to comments as suggested by reviewers v4: Removing trailing spaces v5: Clearing small typo in low-can-cb.cpp on line 142 Change-Id: Ifbcfc3b2d131d1db0b25e472955b21e98cc09f45 Signed-off-by: ydimitrov <y.dimitrov.14@gmail.com>
2018-05-16Fix compilation warningRomain Forlot1-1/+1
Change-Id: I3ea7b3aa91d4251f90a4ccf5da83ae8de7a58db4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-04-17Detect engine state and use it during diagnostic messages subscriptionsJonathan Aillet1-3/+28
Get engine state recurringly by requesting a permanent diagnostic messages request. Use these information to warn that diagnostic request won't have any responses at the moment of subscription if engine is off. Bug-AGL: SPEC-1347 Change-Id: If8bd79bba89acd1c8f5452d3efdbf00a89f8cc77 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-04-17Add possibility to subscribe to a recurring request permanentlyJonathan Aillet1-8/+17
Add possibility to subscribe to a recurring request that won't be deleted when no subscriber is detected. For now, this functionnality is implemented for internal use only. Bug-AGL: SPEC-1347 Change-Id: I48f6f647677596ba7920c4348d5406ea7bf1081b Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-03-15Change subscribed signals search to check filters as wellJonathan Aillet1-3/+2
When a new subscription is made, search in existing subscription for a combination of a signal and a filter instead of searching for just a signal. In this way, each subscription will receive signals according to their requesting filter. Bug-AGL: SPEC-1339 Change-Id: I22cb96a2dbaaf48dbd77025ff1610bde151b19b4 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2017-11-30Fails write request if CAN signal not writableRomain Forlot1-1/+4
Change-Id: I8d75a232ba7fad9cc95f286e521c2451a3a29061 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>