This commit fixes a problem once a bcm socket has been opened
but the following ioctl failed. Before we still return the socket
number instead of returning a negative value as error.
This resulted in problem because the subscription was considered as valid
and binding was continuing using the closed file descriptor.
Bug-AGL: SPEC-2988
Change-Id: Iaa64e7bb00980cb8c0e7080aca238cfb57d628b6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I9794c48d0f7567cc3fdc7dff21b4fcee47296514
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Allows to build a message (J1939,BCM) with a signal and a value.
Bug-AGL: SPEC-2386
Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
Change-Id: Iadca13a927ff83f713f39da441c88356695a1285
|
|
This commit transforms the class can_message_t as the base class
and creates two derived classes: j1939_message_t and can_message_t.
Bug-AGL: SPEC-2386
Change-Id: I6d3afd8e4f5abff2cd0ec4e9910bd52a2893de76
Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This commit implements a new socket class for the j1939 protocol and
prepares the bases classes by modifying the write and read methods.
Bug-AGL: SPEC-2386
Change-Id: I16ba493418a4bb37a0262b61a2a2629be6ab5051
Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh>
Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Improve robustness reading a BCM socket
Adding checks on system calls and remove the initialization of the
struct that will hold the received message, not so much needed in
that case.
- More accurate log message at subscription/unsubscription step whether
this is a FD CAN messages or not and if this a subscription or an
unsubscription that is requested.
- Initialize the full struct of vehicle message to avoid memory warning
about conditionnal jump based on uninitialized bytes.
- Memleak: Free raw pointer on active diagnostic requests
Change-Id: I4bbf4d851c0fa1efdb6fa6034fac3d1dcafa1a73
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Add a flag to CAN message definitions which set the message as using FD
protocol if true.
Use a new generated file with the new FD flag field on the message
definitions.
Change BCM socket "struct" using an union to store the CAN frames either
using the FD struct or the classic non FD struct. A BCM socket can only
one frame type once configured.
Use as much as possible the "struct canfd_frame" in the binding and only
make a difference before writing or reading the socket. From a memory
point of view both struct are identical and only the last member differ
and could hold more data with messages of 64 bytes long. So the
canfd_frame is compatible with the can_frame and can be differentiated
by a flag set in the can_id member.
Remove now unused code processing can_frame.
Keep the diagnostic manager using the classic CAN frame.
Set the maximum number of frames that a BCM socket can handle to 257.
Bug-AGL: SPEC-1980
Change-Id: Ifcc041281ea6745fc25cbd384743761f4446f489
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I036befbfb38b01d046d35a1364c28e0835dcbd41
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Following functions now return 0 on success and negative value
on failure :
o afb_req_subcall
o afb_req_subcall_sync
o afb_service_call
o afb_service_call_sync
Verbosity macros used in v2 bindings now needs to be prefixed
with AFB_ (ERROR -> AFB_ERROR)
Change-Id: Ica4346f215bb142fcda0c6ea15e7074f7091f4cc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|