summaryrefslogtreecommitdiffstats
path: root/low-can-binding/utils/socketcan-bcm.hpp
AgeCommit message (Collapse)AuthorFilesLines
2020-01-09all: Copyright updateRomain Forlot1-1/+1
Bug-AGL: SPEC-2988 Change-Id: I9794c48d0f7567cc3fdc7dff21b4fcee47296514 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-08-12Add feature to build messages and fix some functionsArthur Guyader1-4/+1
Allows to build a message (J1939,BCM) with a signal and a value. Bug-AGL: SPEC-2386 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Change-Id: Iadca13a927ff83f713f39da441c88356695a1285
2019-06-26Change can_message_t class usage for new j1939Romain Forlot1-16/+4
This commit transforms the class can_message_t as the base class and creates two derived classes: j1939_message_t and can_message_t. Bug-AGL: SPEC-2386 Change-Id: I6d3afd8e4f5abff2cd0ec4e9910bd52a2893de76 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2019-06-26Implement a new socket type CAN for j1939 protocolArthur Guyader1-3/+4
This commit implements a new socket class for the j1939 protocol and prepares the bases classes by modifying the write and read methods. Bug-AGL: SPEC-2386 Change-Id: I16ba493418a4bb37a0262b61a2a2629be6ab5051 Signed-off-by: Arthur Guyader <arthur.guyader@iot.bzh> Signed-off-by: Stephane Desneux <stephane.desneux@iot.bzh> Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2018-12-14CAN FD implementationRomain Forlot1-14/+11
Add a flag to CAN message definitions which set the message as using FD protocol if true. Use a new generated file with the new FD flag field on the message definitions. Change BCM socket "struct" using an union to store the CAN frames either using the FD struct or the classic non FD struct. A BCM socket can only one frame type once configured. Use as much as possible the "struct canfd_frame" in the binding and only make a difference before writing or reading the socket. From a memory point of view both struct are identical and only the last member differ and could hold more data with messages of 64 bytes long. So the canfd_frame is compatible with the can_frame and can be differentiated by a flag set in the can_id member. Remove now unused code processing can_frame. Keep the diagnostic manager using the classic CAN frame. Set the maximum number of frames that a BCM socket can handle to 257. Bug-AGL: SPEC-1980 Change-Id: Ifcc041281ea6745fc25cbd384743761f4446f489 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-07-25Make Kernel check not mandatoryRomain Forlot1-0/+2
Use 2 different checks, one specify a mandatory kernel version and the other will output a warning and position a preprocessing variable that can be used in the code to exclude portions of code that use kernel features not available under a certain version. Bug-AGL: SPEC-772 Change-Id: I04523abe96749aeeb185e90eee154fd70a4cbf19 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-06-20Separation Generator to a dedicated repoRomain Forlot1-0/+53
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>