Age | Commit message (Collapse) | Author | Files | Lines |
|
This also change the bit_position to retrieve the bit word starting from the left
or the right of the frame depending on the endianness of the frame layout.
Change-Id: I28658e9d46bd35d8ecabeece317331832229384a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ifdaea3bf0969f15eb70629a92c0293ddeee33491
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Integrate frame layout as a flag instead of a separate boolean
Change-Id: I0fe32fd8a80238006ef89152af25001ecdf018c9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib3e1df0d3741274336c8806ae82082e33d4d3a92
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
No need to use ini-config now that the config is hold by the controller
JSON configuration file.
Bug-AGL: SPEC-2988
Change-Id: If82d22266fb2d592c140b81cda783ee63f1f13be
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I81c01a817cd31d577068350d8445a1df2751bff7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I9a9dec6e577881bbd784bcae1d17ddb244d94599
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Return variable was initialized to 1 instead of 0 and without using J1939
this variable isn't reaffected and so the final test fails.
Bug-AGL: SPEC-2386
Change-Id: I53b7cd757b3b344d66ab18ba9795284105cbcfcc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Convert byte to hex without forgetting '0's.
ex: Before: '10' -> 'a'
After: '10' -> '0a'
Bug-AGL: SPEC-2991
Change-Id: I7346893eaf83aaa9294e48c20cbffd1a61789b51
Signed-off-by: Corentin Le Gall <corentin.legall@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This commit fixes the binding initialization by specifying a
preinit function that parse and load the controller configuration
Bug-AGL: SPEC-2988
Change-Id: I040c401fa2818d056a61a2858829bc4db2cffece
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
RPATH as to be used as target property.
Bug-AGL: SPEC-2988
Change-Id: Ifaa66ceafbe7ed5f7de553b14da2dd8c5b1e8f9d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I8ded9847a5923b3a78afc953551fc6daaf40b355
Signed-off-by: Corentin Le Gall <corentin.legall@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This commit fixes a problem once a bcm socket has been opened
but the following ioctl failed. Before we still return the socket
number instead of returning a negative value as error.
This resulted in problem because the subscription was considered as valid
and binding was continuing using the closed file descriptor.
Bug-AGL: SPEC-2988
Change-Id: Iaa64e7bb00980cb8c0e7080aca238cfb57d628b6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We use the bus name which isn't correct because it isn't the device name.
Bug-AGL: SPEC-2988
Change-Id: I5c9313817a3f3d423f8934cfab03e2cf20d48af2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Remove unecessary brackets and replace if possible
if...else by ternary operator.
Bug-AGL: SPEC-2991
Change-Id: Ibe46b83dea976e050b9cd9eb7ee7ab2c33b63905
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2991
Change-Id: I9ebea118770a9ffe0dd4321408643e76250e3635
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use unsigned int whenever it is possible instead of uint32_t.
This let the compiler decide the type. We do not need to use
uint32_t explicitly for the converter.
Bug-AGL: SPEC-2988
Change-Id: Ic2af875e7435668928c454df76e59c5c43b08407
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Useless tests removed
- Bit operation changed to more readable ones
- Handle correctly mask to decode signal on 1 byte or in-between bytes more clearly.
- using static_cast now instead of C casting method.
- Avoid manual vector initialization and using default constructors instead.
- Avoid using intermediate variables when this isn't necessary.
Bug-AGL: SPEC-2988
Change-Id: I049d65f460109772b57df7572bdac8e6500242e0
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Better using switch case than if...else. This would be more extendable
and readable.
Bug-AGL: SPEC-2988
Change-Id: I5fb03531ad77441bcb7d1620bdb07d82aa6a4eb4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Previous test was always true. This fix the wrong test and then
add the EFF flag correctly on messages using extended
CAN id.
Bug-AGL: SPEC-2988
Change-Id: I69686fd3d5a39ea3a0d1980b4bfa88fe36fb7fe5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
The socket opening wasn't tested and we fails later on another function
using the wrongly opened socket. This would not happens anymore.
Bug-AGL: SPEC-2988
Change-Id: I9b30bd9fc13b99277cbef6f7aeaddadc57ad0b18
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Weird way test to make test are now fixed to be more readable.
Bug-AGL: SPEC-2988
Change-Id: I81d716ac3799c4217e720a13d8ba78a46996a2c3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Just make thing more readable by define variables at the beginning of
functions. And directly assign them if possible.
Also improve format using the same format than in the rest of the project.
Bug-AGL: SPEC-2932
Change-Id: I5cc7685b80734d0eb43a29fc06b2a8434f3469fa
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use configuration from JSON file instead of the old INI file. Now all configuration files
lies within the binding tree.
Bug-AGL: SPEC-2988
Change-Id: Id986d19751db958ad5cf3b7f2b2c5443d4ceb062
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I099b951011442ffaebf75a319236a39553999a41
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change a bit CAN binding define about used protocol. There was a mistake
about BCM define which isn't a protocol at all but a maner to filter
and retrieve CAN message through SocketCAN. Also FD_FRAME was using the
same name than SocketCAN which isn't a good idea, better to distinguis both
of them.
Bug-AGL: SPEC-2988
Change-Id: I255fa03029c7d5f90a33448e5e7692d8c249279b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I28cf984024356925469b4971b993718276d1240f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I433f4f699f3234fc07fcd909cd6b77b84e447ad7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I9198835b96c66c140f8b1d4167828302b9dc4959
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Cleaning and set RPATH to find the low-can library
Change-Id: I6e68a61bbeca385433028a716b9ac6d5e7f28769
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
-Added an attribute to signals that tells if the bit_position
has been swapped.
-Test if bit_size and bit_position gives an "out of range" data
Bug-AGL: SPEC-3022
Change-Id: I589565ca923ec807da2d4f0db7c4c92fb737b579
Signed-off-by: Corentin Le Gall <corentin.legall@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- add enumeration that represents the way of encoding:
enum sign_t
{
UNSIGNED = 0,
SIGN_BIT = 1,
ONES_COMPLEMENT = 2,
TWOS_COMPLEMENT = 3,
SIGN_BIT_EXTERN = 4
};
- the function handle_sign allows to transform value if negative and
return the sign of the value in order to be multiplied at the end ot the
parcing
Bug-AGL: SPEC-3021
Change-Id: I5766a286488170d930422474b4c4f3a8578ca726
Signed-off-by: Clément Bénier <clement.benier@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- can-decoder.cpp: translate_signal() : Tests "frame_layout_is_little".
If false the signal's bit position is changed to fit the layout.
- message-definition.cpp: Added the new attribute
"frame_layout_is_little" and its getter.
- signals.cpp: Added a setter to the bit_position attribute.
- converter.cpp: Added a methode to convert a big endian bit_position
to a right (little endian) bit_position.
Bug-AGL: SPEC-2988
Change-Id: I004c9069eb00f389564927cd12d1b30470c3a59d
Signed-off-by: Corentin Le Gall <corentin.legall@iot.bzh>
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: Iedd493b9e4043290dae0aa9d1d94a3d9179525ae
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: Iaa55b00539b1435b00fe076918d5eda5eeb5db30
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: Ib705ae7c500bb9d3abc863053943298c87896bd2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This is needed to move using a splitted binding/library
model to have plugins linked to the lib as well as the
binding to get there symbols
Bug-AGL: SPEC-2988
Change-Id: I3a9f616078bc7fa9317995ec4300ee2b61aa4b08
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Make as the others bindings using controller and load its configuration file
at preinit step.
diagnostic-manager: Change way to initialize the diag bus
This was kind of hardcoded and now, it is initialized by a configuration key
of the controller configuration JSON file.
Bug-AGL: SPEC-2988
Change-Id: I344c1982893e47600a0b8cd03542de8069a42d24
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Add a space after a comma
Change some aligments
Bug-AGL: SPEC-2988
Change-Id: I5069120f4bbb33742bb4990e2e1f391ec8d5eeb6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: I9794c48d0f7567cc3fdc7dff21b4fcee47296514
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Convert two long types using typedef to get shorter one
Bug-AGL: SPEC-2988
Change-Id: I9f5612def1bce512516a6e1a45711486368bbc51
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Initialize an empty message_set to fill later when loading the Plugins
Add the required method to be able to add a message_set
Bug-AGL: SPEC-2988
Change-Id: I1dc784648f69832de8681184adaccbf5300f831d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2991
Change-Id: I8733a35e4f9cb3d0f2fce818b55a010fec19dc66
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2988
Change-Id: Ic3b9670a2ce9e982220c54f3632f690ee4eea686
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8af34595e4ea4d72af726c6c5db3ac05dda85bf2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Also review some aligment and make more space between bool ops
Bug-AGL: SPEC-2988
Change-Id: I613f294a630caf48eea7bb0c7b9c36b07cbacfbf
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2932
Change-Id: Ifec401451dc541b71dc2f98d25f5c953f1bcf532
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Little optimization in create_rx_filter_can function and
make format coherent on bit operations.
Bug-AGL: SPEC-2988
Change-Id: Ic9c53ba4c937604bbf3500ee89c7b5a5dbca7cfd
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Bug-AGL: SPEC-2779
Change-Id: I672450b51b46082b6a913bef2d6e27d64c49e6fc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
It doesn't matters to know whether or not a can signal is
using standard or extended CAN ID because this could be
retrieved using bit mask on the CAN ID when receiving and
sending.
Bug-AGL: SPEC-2988
Change-Id: Id96c576045bf087df51beb011742ad631336f814
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|