Age | Commit message (Collapse) | Author | Files | Lines |
|
Diagnostic request must have a name to be subscribed. Else, we
can't decode or event push for now.
Change-Id: I0901a71da31320d8598e512614437aceb552713d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change the method to static 'cause it will be call from outside of the class.
Change-Id: I88dcd845559fac7892cd489cd6e8198c143ee2a8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
A CAN message will be considered as a Diagnostic response when its
arbitration ID is between standardized 0x7E8 and 0x7EF.
Checking which request belong to that response will done in later methods
Change-Id: I7a093edf44b62a4552b90fe3d8935f94dc677cf4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Returning to Signal states map avoiding hole in vector allocation as we did
not know how many state a Signal can takes. So a map may be a better choice
Will see.
Change-Id: Ie3ccdbd31296c5c0ebaefc109e75f2e0cde03756
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Main reason for that behavior revert is because of generator that rely
on CAN device name and so we have point on these object by specify the
device name.
Instead of shared pointer between objects, instead binding is based on
device name. With a device name you can get the shared pointer on it using
new static method from can_bus_t object.
Change-Id: I331e0ad8d03c88a15c697d12a9fce3699b0cd962
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
to get able to get difference between classic CAN messages
and diagnostic messages based on name signals prefix.
Change-Id: I696facc58f38150e0457d519dcabffba750a8db3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia39e78aca00a49c7cee5e42d26ba1ef2b49d3709
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib52f22e7bc5bc5d14edbb31ad6006caee23c4098
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
its objects. We don't want random initialization on
boolean value of openxc_DynamicField (has_string, has_numeric...)
else we have a risk that the final decoded and convert into json
object will not be the good one.
Change-Id: If4d69e6ace615fd8e097ba9a04e5482c82b9a7db
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
to a vector.
Change-Id: I185724f2966fecac6659d401751da56d2886ed9d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
always register generic_name into subscribed_signals.
It will be the output on event and make easier to find
the subscribed signals into the map without prefix.
Change-Id: Iaf0060bedb54003b0c77121afd2bd35d832dba25
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
to the ones generated.
Change-Id: I6b0b778f59ac52fe66e36a327f60ae58550ac271
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ifc690cc27028659ffaf5a8a2e9caabc1e0718fd4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
active_diagnostic_request_t (adr)class. It's more logical
to have them here as call about incoming diagnostic CAN
messages are made against adr class not obd2_signal_t that
it's a subset of diagnostic messages.
It's made to handle obd2 requests as well as normal UDS
diagnostic request for constructor proprietary diagnostic
signals.
Change-Id: I96c714640d6ecfa25dfc9942974057c1797eb0e1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Decoding divided in 2 subfunctions dedicated to decode either
pure CAN messages or diagnostic (obd2) message. About now,
a diagnostic request has a name then it will be pushed
on the event_queue as a SimpleMessage. Without name full
details of diagnostic response will be pushed as diagnostic
response. This behavior follows the one from OpenXC.
Change-Id: I255f3f6487fa9511ea47c74606014995a7b0f720
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
attribute as static with a static class method which
will check that the beginning of string argument
matches the prefix.
Change-Id: Idb129c7179391da61447996560957b2791aa9383
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I871ff68afd7f398d4c7d3a550c8926c1f7e67cb3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: If9e3a0511c7ccc703817069a56bd38d7e64ebb09
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1934aa4d9a9d945a32d8e369cf0f36b1e06d3f34
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
the device after so... This was total crap !
Change-Id: I9bb43c3f75c613a5927f342b3c574871c0eb65bb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
It is initiliazed with by default the first CAN bus
device in the CAN bus device list from CAN bus manager.
The object is instancied at configuration_t object first
invokation and after all CAN buses has been initialized then
the diag manager is initialized too.
Change-Id: I4894f2c62f575676c34efec3608b97de8c5326e1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
and const method.
Change-Id: I0f7465af74b1c9a546af45a0d1eea33c93537e0c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
is made on generic_name (without prefix) and returned
vector of string is filled with name with prefix. Then
you can process on them based upon their name differently.
OBD2 signals will generated recurring request on diagnostic
manager and decoding will not be handled the same way too.
Change-Id: I2c5239ef49661941a0a748debe0bd536b2954b3a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I0cfc34f330c531ba5f070542a1cb723be4bcc70a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
is mapped to the address node from json
Change-Id: Ied13067723552c2396337a9f85fe5e1418ba8caf
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
to determine if both object use the same CAN bus device
Change-Id: I97dbf807198a420c305c8fbbd2cb4bfcdda4c294
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
And minor fixes.
Change-Id: Ica55c0708edd86d0aa37e7117b3c3fad551a0167
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: If21021d8905d40d443d4432faeb38f8a3275697c
Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>
|
|
Change-Id: I1076ad90e14815f3d0ab71ca9fa359d1d3c1748d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ice2325441474f1a075140e13dfffa0261106dff7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ief8c66e99c689a362b645ad3b918d8b342ada59a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We have to conform to functions signatures from isotp-c
to have it working.
Change-Id: I429def66f54e53277e87aa99e66292cdb47c1c5f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
into a class.
Added missing include and adjust methods signature.
Change-Id: Id016b452e0b641a14482c288e4713acae941ee1d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I62d9e858409b464dd69ebfae76ca73097fae560e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib44693efc9347fc4fdf40a1748725d5191303199
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I87b1b6961206ae3848cf6aca367698218fe1523e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8253fcbe7edb6673d9f6bcf85d6109800a4cf6e8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib0188ac952f64b3bc2203c0310a21de380c75854
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
that respect the requested signature.
Change-Id: Id10215597d65ecaf280fe6252d78bc74a306958e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib09b084e7202d184abf73cf92fea4afbcf4acf47
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I864a2fe7f974b0f2bf5000f55c2dc71ecf32a314
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
instance to initialize it as it is reference.
Change-Id: I0261a5e2fdca5a84fd736d7ceae837ff9156b935
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Mini simplification of the method... More incoming.
Change-Id: I2e7c2c5226e33265591acc6c8bbbe5f5f670db18
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
from a canfd_frame. A new constructor added ad-hoc.
Change-Id: Id6b909666105da0c4885351db9291aa430d138f0
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
syntax coloration into IDE...
Neat, isn't it !
Change-Id: Ieee2618336be80ddf97ccaa29bc83098a6463c56
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
methods to get their attributes.
Change-Id: Ib96031388356541615cd2c428d3ad1a73c79e215
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
to instanciate an object to decode now.
Change-Id: Id9bf378642ad66b7b4f39d909678ecc5ebb756cc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8aa4430117c401182ef458a06a2aeb08957db1bb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
whole file. Lighter.
Change-Id: I14af5868679e5c65bda9a4395b040cc28af04059
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
as the other type.
Change-Id: I4b3ae3998175613458492a0f02cce06a576cbfa8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|