Age | Commit message (Collapse) | Author | Files | Lines |
|
Change-Id: I5df96540400b833e684001f8fc5fa33ff1892bae
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Made some cleaning about unused things or obsolete.
Review existing comments, adding missing comments.
Reformat some long long constructor.
Change-Id: Ibae247d1295a7a85b49d0ecee473022755d42b8b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Supported boolean member about diagnostic messages is now used. When
a response is received, completed but not successful, then set the diagnostic
message as not supported and clean the request from the queue.
Subscription remains for now, not cool but will be fix soon.
Change-Id: Ia5dc78d4a770f80f144724f4df6eabd2ffd4b8cc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1e43b0aeaff738db11695e77fee23e8c9809f0c1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Diagnostic request must have a name to be subscribed. Else, we
can't decode or event push for now.
Change-Id: I0901a71da31320d8598e512614437aceb552713d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
A CAN message will be considered as a Diagnostic response when its
arbitration ID is between standardized 0x7E8 and 0x7EF.
Checking which request belong to that response will done in later methods
Change-Id: I7a093edf44b62a4552b90fe3d8935f94dc677cf4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Main reason for that behavior revert is because of generator that rely
on CAN device name and so we have point on these object by specify the
device name.
Instead of shared pointer between objects, instead binding is based on
device name. With a device name you can get the shared pointer on it using
new static method from can_bus_t object.
Change-Id: I331e0ad8d03c88a15c697d12a9fce3699b0cd962
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I752db65cb3fbca4d33b932f3a0c597adfaf79903
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Implements event_loop logic.
Change-Id: Ia5ac32820a0421bbcb69d8b0dd3bea2b7b582444
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Control size manually, don't rely on STL container.
Change-Id: Iede2f9b233c5b8a6dc77c9b146ffc92da8e7a989
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I341d29d217b2a92652e9985d8c93829e0211bddc
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Regular events is made launch a timerfd event from binder event loop and then
in the event handler, reschedule next launch in the future based upon the
signal frequency.
Change-Id: I0b1e84eb2135474f4bcc5ee256ba513eea4035a6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
while adding the request. It is more logic to make that here
than in the subscription operation.
Change-Id: I19b29bc11c5fb6e5828a0bf189fac1333b0199ed
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
between diagnostic manager vector.
Change-Id: I9ea196b5dc5bbf2dd4509080a9a58d754fa42b6c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Decoding divided in 2 subfunctions dedicated to decode either
pure CAN messages or diagnostic (obd2) message. About now,
a diagnostic request has a name then it will be pushed
on the event_queue as a SimpleMessage. Without name full
details of diagnostic response will be pushed as diagnostic
response. This behavior follows the one from OpenXC.
Change-Id: I255f3f6487fa9511ea47c74606014995a7b0f720
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
method to retrieve the active_diagnostic_request.
Change-Id: Icfba704e40be211021dc81ec18fa3602d736afdb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
When subscribed, the signal is added to recurring request list
of diagnostic manager and an event is added to the systemd
event loop with timer set using frequency parameter from the
requested signal.
Change-Id: I4d604c498047d7744c090b7f03fce0f2b427fd01
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
It is initiliazed with by default the first CAN bus
device in the CAN bus device list from CAN bus manager.
The object is instancied at configuration_t object first
invokation and after all CAN buses has been initialized then
the diag manager is initialized too.
Change-Id: I4894f2c62f575676c34efec3608b97de8c5326e1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I0cfc34f330c531ba5f070542a1cb723be4bcc70a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8a518540b54552d60c6fd1054a0fc41dda5400b4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Fix subsequents bugs into the other depending class
diagnostic manager
Change-Id: I8920c489fc15a61a36ff29d58aab59c2e6388f85
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Needed overload of operator and constructor set for
active_diagnostic_message_t class. Without we can't make
the basic operation needed by the manager.
Get rid of original raw pointer on "entry" which avoid some
tests.
It miss the acceptance filters implementations for now.
Change-Id: I1ca61ff843c13255af6d9a60ce72a8b8bc9d1c18
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
And minor fixes.
Change-Id: Ica55c0708edd86d0aa37e7117b3c3fad551a0167
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
objects initialized that can be grabed after at runtime.
Don't know the impact on performance for now about maximum
limit.
Change-Id: I220614d479b8254ae0efda66380e96434bcbfbb2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
We have to conform to functions signatures from isotp-c
to have it working.
Change-Id: I429def66f54e53277e87aa99e66292cdb47c1c5f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
a default constructor.
It is needed to initialize configuration_t correctly as
it allocate a diagnostic manager but do not initialize it
unless it is needed later. There is no need to initialize it
if we do not send and receive diagnostic requests.
Change-Id: I3d52d1ea92454e7b065479a2f0dd54a291ddd991
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I7d7a96b45323f698e884c4db289370eec199d990
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
It will hold communication through uds-c lib allowing
to communication with diagnostic protocol obd2. It is
attached to can_bus_dev_t class 'cause it must regularly
send CAN message through it.
Change-Id: I2d9d8dfaca10e9865bf82b0ae83e65490ca982f8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|