summaryrefslogtreecommitdiffstats
path: root/src/diagnostic/diagnostic-manager.hpp
AgeCommit message (Collapse)AuthorFilesLines
2017-03-16Make diagnostic manager initialization processus.Romain Forlot1-5/+6
It is initiliazed with by default the first CAN bus device in the CAN bus device list from CAN bus manager. The object is instancied at configuration_t object first invokation and after all CAN buses has been initialized then the diag manager is initialized too. Change-Id: I4894f2c62f575676c34efec3608b97de8c5326e1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Keep raw pointer for now as we have to move them around vector.Romain Forlot1-8/+8
Change-Id: I8a518540b54552d60c6fd1054a0fc41dda5400b4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Finalize the class active_diag... to get it compile.Romain Forlot1-0/+1
Fix subsequents bugs into the other depending class diagnostic manager Change-Id: I8920c489fc15a61a36ff29d58aab59c2e6388f85 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Adding requests to diagnostic manager implemented.Romain Forlot1-4/+14
Needed overload of operator and constructor set for active_diagnostic_message_t class. Without we can't make the basic operation needed by the manager. Get rid of original raw pointer on "entry" which avoid some tests. It miss the acceptance filters implementations for now. Change-Id: I1ca61ff843c13255af6d9a60ce72a8b8bc9d1c18 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: include statement with wrong path.Romain Forlot1-8/+11
And minor fixes. Change-Id: Ica55c0708edd86d0aa37e7117b3c3fad551a0167 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Added constructor to get vector initialized with defaultRomain Forlot1-12/+12
objects initialized that can be grabed after at runtime. Don't know the impact on performance for now about maximum limit. Change-Id: I220614d479b8254ae0efda66380e96434bcbfbb2 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Add necessary to be able to initialize diagnostic manager shims.Romain Forlot1-1/+4
We have to conform to functions signatures from isotp-c to have it working. Change-Id: I429def66f54e53277e87aa99e66292cdb47c1c5f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Changing to a raw pointer can_bus_dev member and addRomain Forlot1-1/+3
a default constructor. It is needed to initialize configuration_t correctly as it allocate a diagnostic manager but do not initialize it unless it is needed later. There is no need to initialize it if we do not send and receive diagnostic requests. Change-Id: I3d52d1ea92454e7b065479a2f0dd54a291ddd991 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16FormatRomain Forlot1-27/+27
Change-Id: Ie9159b039e468e511b497884816453093048aa80 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Better use a referenceRomain Forlot1-2/+2
Change-Id: Ie060009315c99919271ac706fdc1ab384e3d7218 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Respect the signature requested by uds-c lib.Romain Forlot1-2/+2
Change-Id: I7d7a96b45323f698e884c4db289370eec199d990 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Introducing diagnostic manager class.Romain Forlot1-0/+77
It will hold communication through uds-c lib allowing to communication with diagnostic protocol obd2. It is attached to can_bus_dev_t class 'cause it must regularly send CAN message through it. Change-Id: I2d9d8dfaca10e9865bf82b0ae83e65490ca982f8 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>