1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
|
/* Automatically generated nanopb constant definitions */
/* Generated by nanopb-0.3.1 at Tue Sep 16 23:03:27 2014. */
#include "openxc.pb.h"
#if PB_PROTO_HEADER_VERSION != 30
#error Regenerate this file with the current version of nanopb generator.
#endif
const pb_field_t openxc_VehicleMessage_fields[7] = {
PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_VehicleMessage, type, type, 0),
PB_FIELD( 2, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, raw_message, type, &openxc_RawMessage_fields),
PB_FIELD( 3, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, translated_message, raw_message, &openxc_TranslatedMessage_fields),
PB_FIELD( 4, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, diagnostic_response, translated_message, &openxc_DiagnosticResponse_fields),
PB_FIELD( 5, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, control_command, diagnostic_response, &openxc_ControlCommand_fields),
PB_FIELD( 6, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, command_response, control_command, &openxc_CommandResponse_fields),
PB_LAST_FIELD
};
const pb_field_t openxc_RawMessage_fields[4] = {
PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_RawMessage, bus, bus, 0),
PB_FIELD( 2, UINT32 , OPTIONAL, STATIC , OTHER, openxc_RawMessage, message_id, bus, 0),
PB_FIELD( 3, BYTES , OPTIONAL, STATIC , OTHER, openxc_RawMessage, data, message_id, 0),
PB_LAST_FIELD
};
const pb_field_t openxc_ControlCommand_fields[4] = {
PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_ControlCommand, type, type, 0),
PB_FIELD( 2, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_ControlCommand, diagnostic_request, type, &openxc_DiagnosticRequest_fields),
PB_FIELD( 3, ENUM , OPTIONAL, STATIC , OTHER, openxc_ControlCommand, action, diagnostic_request, 0),
PB_LAST_FIELD
};
const pb_field_t openxc_CommandResponse_fields[4] = {
PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_CommandResponse, type, type, 0),
PB_FIELD( 2, STRING , OPTIONAL, STATIC , OTHER, openxc_CommandResponse, message, type, 0),
PB_FIELD( 3, BOOL , OPTIONAL, STATIC , OTHER, openxc_CommandResponse, status, message, 0),
PB_LAST_FIELD
};
const pb_field_t openxc_DiagnosticRequest_fields[10] = {
PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_DiagnosticRequest, bus, bus, 0),
PB_FIELD( 2, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, message_id, bus, 0),
PB_FIELD( 3, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, mode, message_id, 0),
PB_FIELD( 4, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, pid, mode, 0),
PB_FIELD( 5, BYTES , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, payload, pid, 0),
PB_FIELD( 6, BOOL , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, multiple_responses, payload, 0),
PB_FIELD( 7, DOUBLE , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, frequency, multiple_responses, 0),
PB_FIELD( 8, STRING , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, name, frequency, 0),
PB_FIELD( 9, ENUM , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, decoded_type, name, 0),
PB_LAST_FIELD
};
const pb_field_t openxc_DiagnosticResponse_fields[9] = {
PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_DiagnosticResponse, bus, bus, 0),
PB_FIELD( 2, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, message_id, bus, 0),
PB_FIELD( 3, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, mode, message_id, 0),
PB_FIELD( 4, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, pid, mode, 0),
PB_FIELD( 5, BOOL , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, success, pid, 0),
PB_FIELD( 6, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, negative_response_code, success, 0),
PB_FIELD( 7, BYTES , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, payload, negative_response_code, 0),
PB_FIELD( 8, DOUBLE , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, value, payload, 0),
PB_LAST_FIELD
};
const pb_field_t openxc_DynamicField_fields[5] = {
PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_DynamicField, type, type, 0),
PB_FIELD( 2, STRING , OPTIONAL, STATIC , OTHER, openxc_DynamicField, string_value, type, 0),
PB_FIELD( 3, DOUBLE , OPTIONAL, STATIC , OTHER, openxc_DynamicField, numeric_value, string_value, 0),
PB_FIELD( 4, BOOL , OPTIONAL, STATIC , OTHER, openxc_DynamicField, boolean_value, numeric_value, 0),
PB_LAST_FIELD
};
const pb_field_t openxc_TranslatedMessage_fields[5] = {
PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_TranslatedMessage, type, type, 0),
PB_FIELD( 2, STRING , OPTIONAL, STATIC , OTHER, openxc_TranslatedMessage, name, type, 0),
PB_FIELD( 3, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_TranslatedMessage, value, name, &openxc_DynamicField_fields),
PB_FIELD( 4, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_TranslatedMessage, event, value, &openxc_DynamicField_fields),
PB_LAST_FIELD
};
/* Check that field information fits in pb_field_t */
#if !defined(PB_FIELD_32BIT)
/* If you get an error here, it means that you need to define PB_FIELD_32BIT
* compile-time option. You can do that in pb.h or on compiler command line.
*
* The reason you need to do this is that some of your messages contain tag
* numbers or field sizes that are larger than what can fit in 8 or 16 bit
* field descriptors.
*/
PB_STATIC_ASSERT((pb_membersize(openxc_VehicleMessage, raw_message) < 65536 && pb_membersize(openxc_VehicleMessage, translated_message) < 65536 && pb_membersize(openxc_VehicleMessage, diagnostic_response) < 65536 && pb_membersize(openxc_VehicleMessage, control_command) < 65536 && pb_membersize(openxc_VehicleMessage, command_response) < 65536 && pb_membersize(openxc_ControlCommand, diagnostic_request) < 65536 && pb_membersize(openxc_TranslatedMessage, value) < 65536 && pb_membersize(openxc_TranslatedMessage, event) < 65536), YOU_MUST_DEFINE_PB_FIELD_32BIT_FOR_MESSAGES_openxc_VehicleMessage_openxc_RawMessage_openxc_ControlCommand_openxc_CommandResponse_openxc_DiagnosticRequest_openxc_DiagnosticResponse_openxc_DynamicField_openxc_TranslatedMessage)
#endif
#if !defined(PB_FIELD_16BIT) && !defined(PB_FIELD_32BIT)
/* If you get an error here, it means that you need to define PB_FIELD_16BIT
* compile-time option. You can do that in pb.h or on compiler command line.
*
* The reason you need to do this is that some of your messages contain tag
* numbers or field sizes that are larger than what can fit in the default
* 8 bit descriptors.
*/
PB_STATIC_ASSERT((pb_membersize(openxc_VehicleMessage, raw_message) < 256 && pb_membersize(openxc_VehicleMessage, translated_message) < 256 && pb_membersize(openxc_VehicleMessage, diagnostic_response) < 256 && pb_membersize(openxc_VehicleMessage, control_command) < 256 && pb_membersize(openxc_VehicleMessage, command_response) < 256 && pb_membersize(openxc_ControlCommand, diagnostic_request) < 256 && pb_membersize(openxc_TranslatedMessage, value) < 256 && pb_membersize(openxc_TranslatedMessage, event) < 256), YOU_MUST_DEFINE_PB_FIELD_16BIT_FOR_MESSAGES_openxc_VehicleMessage_openxc_RawMessage_openxc_ControlCommand_openxc_CommandResponse_openxc_DiagnosticRequest_openxc_DiagnosticResponse_openxc_DynamicField_openxc_TranslatedMessage)
#endif
/* On some platforms (such as AVR), double is really float.
* These are not directly supported by nanopb, but see example_avr_double.
* To get rid of this error, remove any double fields from your .proto.
*/
PB_STATIC_ASSERT(sizeof(double) == 8, DOUBLE_MUST_BE_8_BYTES)
|