Age | Commit message (Collapse) | Author | Files | Lines |
|
Some function that are now included in the controller submodule
do not need to be in the composer as well. Also initialize
sources and signals in the same way .
JSON configuration needs to be updated to fit this changes
Change-Id: I2043791e7ee80f8350f33ed15bdf9980c0773b82
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ic1a0621d9c0bbbffb7dcc0f9daf148a372818cdb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This has changed and is now explicitly launched because
last step of Controller configuration doesn't execute it.
Change-Id: I104011b912172da62114b62eeab90c76e41459dd
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Back in normal configuration file
- Remove builtin special callback as it is just a plugin after all
- Rename main configuration files to get it works on a target
board.
Change-Id: I69165c47e5e58eb519e727cfdd83ee628d90abba
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I0cff16c1d44b9363522fde7c6c9b2bd10ba376ac
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Later integrated in controller submodule
Change-Id: I7d5c7431e60fc16cc2053747674fe4f14efd6a14
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I055d1ad1f9f1305009f4237e56566784e2ecdcfb
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Controller will now handle loading additional files
from section.
Context retrieving change a bit, now we have source context
and plugin context.
Update json unpacking and packing.
Cleaning, format.
Change-Id: Ie7a4721f6b703796a0dac1a236922427f4755dc5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
New version of controller as a library. Loading additionnals
files from each sections.
Change-Id: I4f5e78d0baf9650cb8d1cc1da26f8e1fd73b792c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1a61b49f55e4daa305800e754a14b6041aa81b34
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Stores sourceAPI as shared_ptr too.
Change-Id: I2dcd919b3053f29812a9bece14feb4f620f23ce3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Be able to tweak retention value for each signal in seconds
Change-Id: I1cabe48a2660cdeb2e9b32b277e7c819c6b49bd9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- SourceAPI now holds share_ptr of Signal
- Signal are stored in a map<string,signal> that change
way to browse the signals
- subscribed property included in SourceAPI.
- Clean old code
- renaming struct SignalValue->signalValue
Change-Id: Ic5c28296ddd7197c6562e12fbc91c504c1cc0b4d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Adding new object holding signals subscribed and afb event
that observes Signals using Reactive response observer design
pattern
Change-Id: I96647d36e0d27c25a399c1b3789621a803a845b6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I7bbe972254d60f89cb26c98ea8519af087d8ae90
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ifb21916bfb4c9c1be0fe68c1a88ada342d18ffe4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib3256f5c89197a91d2bbfca7a92774e91de6f664
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia562fbd90aaeaa57c1c731d0f66dd31865db7e71
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Added LUA library at link
- Make app-template crash build if a checked file fails
- Fix old defined variable CONTROL_LUA_PATH to a default
one in the binding data directory
- Add an example with unit conversion made in LUA
Change-Id: I1b4712bde32a38044ad6b14ebd38b6782fd01fe9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Argument for each signal subscription. (getSignalsArgs)
- differentiation between Signal as raw signal from another API
and virtual signal depending upon other signals
- changing way to specify function with uri that specify everythings
that could be needed to invoke a function.
Change-Id: I8917c5ae3c2c1e3fa48ddfdda41fc75eaba32bb7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Can't shared C++ symbol easily with plugin so workaround
with a separate static function that handle the job
Change-Id: I1208b51bc47c2daa5f08e10b25260cf206f90aed
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I453ddc0ca374436275e7d76cdc27b3d843a2770f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Icb923f87df2be8eb664106bc9077b3a8221dd3ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I2f9509d4b6aa63a16df8db2187810337fd802ef4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idd8d8987ccabef381f6d79c1d508930a2d4bae3c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I2bb38bffdd92602659670901b8442201b7c56214
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|