Age | Commit message (Collapse) | Author | Files | Lines |
|
Some function that are now included in the controller submodule
do not need to be in the composer as well. Also initialize
sources and signals in the same way .
JSON configuration needs to be updated to fit this changes
Change-Id: I2043791e7ee80f8350f33ed15bdf9980c0773b82
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Last timestamp and value is those ones directly store as object's
attributes not the last from the history. Simple...
Change-Id: Id2c808a1b236dfa36821cf9fc5a5bcd6a4114f10
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Improve GPS plugin to be able to calculate the heading also remove
the builtin plugin that was an error. We need to pass GPS plugin in
C++ to be able to use the context.
Handle "double" and "int" signal's value.
Change-Id: I6d902e4ac76a0e933326c0b4c43922645c9c5a4c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
The notify was in fact called 2 times.
It is attended that a callback should "set"
the signal value to record it.
Setting the signal's value already call notify which
an action should do at the end. Notifying has a
meaning only if a signal value has been modified.
Change-Id: I4a8128317a88bf7459b2c4aa0f575c4b2524e816
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This is the default precision returned by the kernel
when calling get_clocktime(), so this avoid useless
division to get a less precise time. Also signaling
event should have this kind of precision to be able
to correctly debugging system on signals heavy load.
Change-Id: I010b98305cff7387787fd8f8a1e8a0f9107a170a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I4c2a31f5c395c0d85ec810b25fb88c70cf691375
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Adding != operator to Signal class
This operator is needed to exclude signal
inclusion in notify function and make
possible to add a signal at last position
Change-Id: I95f3434019383e52928c37f396aae938f2cfae05
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Fix memleak: RRelease the Signal JSON representation once used
- Change equality condition between signals
- Use a REALTIME clock to retrieve the timestamp if not provided by
the signal. This is the most simple to date a signal and
use that time for further usage.
- Add a method to retrieve the last_timestamp value from
a signal
This with the commit from ctl-utilities submodule
"8ff0fe3c454ea32ba383a3cfa9c4e91237d6c494" fixes the
issue.
Change-Id: Ifed66796f92d789c80f10b161318f6bef788dda7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
By default subscription argument request from signal
are passed if present, else the one from the signal's
source if present.
If nothing is specified for sources then argument
is set as a NULL pointer.
Change-Id: I18db0a9922039f41d475cd08758a2afd4acaa9d4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ic2f8ebee552ce982f858fe6ee93db2508a290617
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
no reason to keep it as pointer, and simpler to initiaze
it at construction time.
Change-Id: I0aee4483c834e66651d80998de81c99799451ff5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I0cff16c1d44b9363522fde7c6c9b2bd10ba376ac
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Keeping persistence between call data are kept in that member
also subscription Action now use getSignals_ context and no more
the signal one, this is more accurate and simples
Change-Id: Idd7c56ba30f1daa9eaf9b99a7261d58189ef0bb2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Values has to be set.
Change-Id: Ia8fcd23e68b79de5cd0316c81341ac41643750b5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
And replace free calls by delete because operator
new was used.
Change-Id: Ifb0d301b0a09dd83e3ad574c97e02bd8af072ae6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Fix a memory squashing bug that segfault binder when
loading directory searching for binding.
Change-Id: Iedc6747d8ce49e7ff5fc2013bb7d03b5b553b89c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Controller will now handle loading additional files
from section.
Context retrieving change a bit, now we have source context
and plugin context.
Update json unpacking and packing.
Cleaning, format.
Change-Id: Ie7a4721f6b703796a0dac1a236922427f4755dc5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
New version of controller as a library. Loading additionnals
files from each sections.
Change-Id: I4f5e78d0baf9650cb8d1cc1da26f8e1fd73b792c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1a61b49f55e4daa305800e754a14b6041aa81b34
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Icc23f135d4e65d6de131a60b978677e549738d78
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I92f9d242cd108d8355069a4a63b391a5302d27a8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Stores sourceAPI as shared_ptr too.
Change-Id: I2dcd919b3053f29812a9bece14feb4f620f23ce3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Be able to tweak retention value for each signal in seconds
Change-Id: I1cabe48a2660cdeb2e9b32b277e7c819c6b49bd9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- SourceAPI now holds share_ptr of Signal
- Signal are stored in a map<string,signal> that change
way to browse the signals
- subscribed property included in SourceAPI.
- Clean old code
- renaming struct SignalValue->signalValue
Change-Id: Ic5c28296ddd7197c6562e12fbc91c504c1cc0b4d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib1d5da084b3a39fbfc9816070aba008e3486cfae
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ic404c098f316106abe1918c3cd100ae047f4f555
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I2fa4e1dc81f5dff852e619a425b8caf26b94b55a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib3256f5c89197a91d2bbfca7a92774e91de6f664
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia562fbd90aaeaa57c1c731d0f66dd31865db7e71
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Added LUA library at link
- Make app-template crash build if a checked file fails
- Fix old defined variable CONTROL_LUA_PATH to a default
one in the binding data directory
- Add an example with unit conversion made in LUA
Change-Id: I1b4712bde32a38044ad6b14ebd38b6782fd01fe9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Argument for each signal subscription. (getSignalsArgs)
- differentiation between Signal as raw signal from another API
and virtual signal depending upon other signals
- changing way to specify function with uri that specify everythings
that could be needed to invoke a function.
Change-Id: I8917c5ae3c2c1e3fa48ddfdda41fc75eaba32bb7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I12efd66777cbc5217dfd68827f40727577df1406
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I40799d054e56b3ae9462963d317d8fb458a21122
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia080cddac3973998a2dc8f8a143489298d6c8504
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Context passing variables not working well
Change-Id: Ibc67bef353e5cc2e53ef9e5579d106baab92a604
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I453ddc0ca374436275e7d76cdc27b3d843a2770f
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Icb923f87df2be8eb664106bc9077b3a8221dd3ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I2f9509d4b6aa63a16df8db2187810337fd802ef4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idd8d8987ccabef381f6d79c1d508930a2d4bae3c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|