Age | Commit message (Collapse) | Author | Files | Lines |
|
Fix a memory squashing bug that segfault binder when
loading directory searching for binding.
Change-Id: Iedc6747d8ce49e7ff5fc2013bb7d03b5b553b89c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Controller will now handle loading additional files
from section.
Context retrieving change a bit, now we have source context
and plugin context.
Update json unpacking and packing.
Cleaning, format.
Change-Id: Ie7a4721f6b703796a0dac1a236922427f4755dc5
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
New version of controller as a library. Loading additionnals
files from each sections.
Change-Id: I4f5e78d0baf9650cb8d1cc1da26f8e1fd73b792c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I1a61b49f55e4daa305800e754a14b6041aa81b34
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Stores sourceAPI as shared_ptr too.
Change-Id: I2dcd919b3053f29812a9bece14feb4f620f23ce3
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Be able to tweak retention value for each signal in seconds
Change-Id: I1cabe48a2660cdeb2e9b32b277e7c819c6b49bd9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- SourceAPI now holds share_ptr of Signal
- Signal are stored in a map<string,signal> that change
way to browse the signals
- subscribed property included in SourceAPI.
- Clean old code
- renaming struct SignalValue->signalValue
Change-Id: Ic5c28296ddd7197c6562e12fbc91c504c1cc0b4d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Adding new object holding signals subscribed and afb event
that observes Signals using Reactive response observer design
pattern
Change-Id: I96647d36e0d27c25a399c1b3789621a803a845b6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ic1561e34d01be2b15618536fe6ef01066c184520
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ib3256f5c89197a91d2bbfca7a92774e91de6f664
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia562fbd90aaeaa57c1c731d0f66dd31865db7e71
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Added LUA library at link
- Make app-template crash build if a checked file fails
- Fix old defined variable CONTROL_LUA_PATH to a default
one in the binding data directory
- Add an example with unit conversion made in LUA
Change-Id: I1b4712bde32a38044ad6b14ebd38b6782fd01fe9
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Argument for each signal subscription. (getSignalsArgs)
- differentiation between Signal as raw signal from another API
and virtual signal depending upon other signals
- changing way to specify function with uri that specify everythings
that could be needed to invoke a function.
Change-Id: I8917c5ae3c2c1e3fa48ddfdda41fc75eaba32bb7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Icb923f87df2be8eb664106bc9077b3a8221dd3ce
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I2f9509d4b6aa63a16df8db2187810337fd802ef4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Idd8d8987ccabef381f6d79c1d508930a2d4bae3c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|