Age | Commit message (Collapse) | Author | Files | Lines |
|
Display the tests results depending on the chosen
format or inform the user of the error and displaying
in that case the binder(s) log output.
Change-Id: Id1d91d55b182969e8a5a8d7aed319d16aec0db19
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This commit adds a test that ensures that the timeout waiting
an event expires correctly and that we correctly wait for the
indicated time.
Change-Id: I70c5aaf8d66588b4073cb772163d20344fdaf77c
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
On a target, the binder process name is taken from the widget "id",
now the native launcher script also launches the binder using the widget "id".
As the controller searches its configuration file using the binder process middle name
we need to differentiate between both "id" otherwise the wrong configuration file is used.
The commit renames configuration file according to the new "id".
Change-Id: I4a596dd1d54201a671bb68bf9aca6904286322c6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This adds some instructions to build test widget using SDK
and basic instruction on how to test natively on your host
as well as on a target board.
Change-Id: I9af1a099c57fcd3e330fb505b16426309f3fb93d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
directly use app framework binder api v3
Change-Id: Ifb12568026772b32dad94decd2c32eeab904968d
Signed-off-by: Clément Bénier <clement.benier@iot.bzh>
|
|
Display an error and exit if no JSON test configuration
file found. Else it would kill your user session.
Change-Id: Idbd92c47fafc5c1b75397ec729b29abb49c607b1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Without that separation you need to specify a nil argument
before your setUp and tearDown functions in your test definition.
Change-Id: Ied7d5b057075478ccf2c4cefc954e9a0f6814bb7
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Using aftest and aft-aftest api name to self test was
difficult because of searching file using the binder process
name which could be the same although api name were diffirent.
Change-Id: Id14e30024f0b98c29feed5b707ab9dc8b74d3552
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I594c31238a0afc47f90cc97be82f3044a5052d67
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I57ac01794ea92e235cb105acb22ab44f5566268b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use one output file by test suite executed with the according extension
depending upon the output type chosen.
Change-Id: I1804287fc56e4ee2b6df9f672d94553a3d947d49
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Signed-off-by: Jan-Simon Möller <jsmoeller@linuxfoundation.org>
|
|
Adding objects to events section using the controller function
to create a mock-api.
Change-Id: Ic538c02f08b2f4f3376ffa6e9b9ffcbef1592599
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Because may the users doesn't set to exit the binder at the end
in the LUA so it has to be killed by the script. Then every case
are covered.
Change-Id: I3967b296ca8eafc65bb8109c57d2b8b2de582583
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This reset the contextual functions that trigger before and after
tests between each files loaded. Then context is set by file and not
by the API's verb of the test binding. This is more an intuitive
behavior.
Change-Id: I76716dd19d23b715690b74d9b67253dffd01c12d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I895ca559a1ebf313c25252b38883f54d45da8bd8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I8ac2a69aeb1f6cf6daeb560bd38f92c411dbaf58
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
For native build and test purposes you need to start 2
bindings to be able to test correctly the afb-test binding.
The first one will answer on the main API name afTest and the
second to launch the test.
This is the closest test case similar to a test on a target
board.
Change-Id: I6b961c0e41cdd3eef387b7f5156ed334e8f6c3de
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This protect the file read to avoid crashing if no file has
been found and display an error.
Protect with double-quote the path to avoid 'find' error
if space are part of the path.
Change-Id: I3a27ca9d2566edd5f1b9cd301153e0ab735a177a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
-Changed 0_ProjectTree.md to only show what's interesting.
-Made further explanations on how to organize and integrate test files.
-Updated 2_LaunchTheExample.md, now explains the new way to launch tests.
-Also added the result of a test launched on a target.
-Added a configuration example in 1_BindingConfiguration.md .
Change-Id: I4c4ed1cef5e914a8179a6823489791e6756106b6
Signed-off-by: CorentinLGS <corentinlgs@gmail.com>
|
|
Remove the debug log messages.
Display the results of tests at the end.
Change-Id: I38ec1a6807a8e7de483545fd3346327fe1847f73
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
-Deleted gendocs.sh, docs/_layout and docs/resources.
-Splited book.json to match new format.
-Changed description in README.md
Change-Id: I9835bf64ea2f0b6b3ca6cfd9f1ec8c720b4618c9
Signed-off-by: CorentinLGS <corentinlgs@gmail.com>
|
|
Binder FF.RC4 provides the missing define afb_service_call[_sync]_legacy
which doesn't fit with define in the controller as the first argument
API is already given by the app framework binder.
Change-Id: I5aa6dbbbf6cad37377d933ff4de8466a6a4d9a34
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Submodule conf.d/app-templates f0b24b0..52ae181:
> Fix: typo
Change-Id: I0a233b64eb592d3b9254b3bdb13046d8ce41f866
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Also separate helloWorld example binding test from self aft tests
Change-Id: I5b7c48b38cc6629c3edc97d280d7f9228451b337
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Fix: expected data table structure in callbackEvent
- Testing event received with a timeout is meaningless since
the event are pushed on afb-test request. So They are already
received at the assertion moment.
- Wrong test waiting for a verb error.
Change-Id: I1cec211f7fe4c37d4c238439e8a9a633121a6cf0
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Cleaning, there is no point to test if we do not receive events
Change-Id: I28bc46d7b933c851f716466ad0d97b56cca3d95b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
As it is the most common used in AGL environment. Ptest is almost
the same and only need a little sed script to be compatible and
Jenkins have a TAP plugin that also handle TAP test results.
Change-Id: I9f367a01417121aad35753536adece27b3ca0f7d
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This is made to have all tests results in 1 place else they
will lie in the binder log journal.
Change-Id: I60293230bbd8252d1ed947bba7c9583f5957e01e
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This lets the test lua scripts use this variable to be able
to retrieve fixtures files which lie in the 'var' directory
Change-Id: Iad321706bd05dfb8e5f0423a15d710fdc540c154
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Create a cleanup function to be called in case of error
- Assume the app home directory to be able to retrieve the
test results log file.
- Use a sed script to make the output of test results compliant
with ptest.
Change-Id: I6e3f0ca59a1ca8fc7537955c440a4c55196b9ec6
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
For compatibility between different binding versions
Submodule app-controller-submodule e3f2c45...4386ec5:
> Migration to v3
> Adds v3 function to get binding settings
> New function returning the binding root directory
> Change the default GLOB pattern
> Fix wrong computed length
> Add path to the installed widget path.
> Controller: Converted README to a gitbook version.
Submodule conf.d/app-templates 9c1a0fb..f0b24b0:
> Rollback about TEST build type
> Adding a TEST build type
> Change default compilation options.
> Test widget only if there are test materials
> Handles more test LABELS.
> Missing flag for COVERAGE build type
> Create a test widget
Change-Id: I4f96cc6773ec4da7eba96f243d6bf06170ef0cb0
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Wrong file name searched specified in the log message.
Change-Id: I39d70797191de4cee966dee2793e866b7ab3cbf4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Fix: getrootdir function usage that needs the context to be passed.
This closes file handle before going to the next one. This was
causing a segfault on the second file reading.
Change-Id: I1d7459e29f9b8725dcbce1a277a10d3adcd4c856
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Then it is possible to use Yocto to retrieve it and include it
in the rpm that will be installed in the target.
Change-Id: I2038ca67ea62865351436daf48193d1b972d65e2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: I09f174c99488ff104aaa7995e1575a5e5aa3a0c0
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This resolv the link to the binding aftest library then set
the dir path to the widget installation location.
Depends-On: I5db247fd9925065684e036d8d458c2131006f9db
Change-Id: I4c49b930181a813d0ef3c2d873455a4ac7721206
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Use new AppFw feature to find a library location.
This will help to find the library that hold a binding which could create several different APIs.
Depends-On: I70aad7d523ece7a2ae0058b79708a02ef81144e2
Change-Id: I1454eb8ea661d4d3854b344cb989fc05e2704a77
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Version is handled by the app-templates if PROJECT_VERSION
is not set.
Adjusts pattern to match lua files location
Change-Id: I40052e86d5f55ef2c43f9f1266e1ac3fe14db0c8
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This script will be in charge of launching the test binding
app.
Change-Id: I34d74d173f9f00d916a61b912b0e285b350ead99
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
- Tested changed assertEvtGrpReceived functions
- Updated doc about it
Change-Id: I91725152e54ebba9d65e501da54a72801699c760
Signed-off-by: Corentin Le Gall <corentinlgs@gmail.com>
|
|
This adding is to find LUA plugins that aren't located to the same
directory than C plugins. It uses 2 variables INSTALL_PREFIX and
CMAKE_INSTALL_PREFIX because of CMake's files inclusion order in the
current app-templates. This will be needed until app-templates migrate
as a CMake module.
Change-Id: I06bffbc60f132c08eca0cf0793d7c3f25f0524ad
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Submodule afb-helpers 764c355..f0ce5b6:
> wrap-json: Fix duplicated lines in header file
Submodule app-controller-submodule b79a761..4e30eb1:
> New defaults useful functions on lua table
> More precise log message when loading a Lua file
> Fix: wrong legacy function signature
Submodule conf.d/app-templates f94e45e..9c1a0fb:
> Fix: interpreted '&' character
> More accurate comment about widget template file.
Change-Id: I5d18b1005e797f2297c6766266abcbdbc65816e4
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
snprintf include the terminating character when it writes to
the buffer.
Change-Id: Idca1050deb9af64de1fdd4f08744166b2fa144b1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
This make table_size function accessible by default in all
lua scripts.
Depends-On: Ia549315e305dd7d02b975a3e8a1278c4ab709eec
Change-Id: I312c79581ab3eaef72c1b5725982a70515c62a2a
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change the way to assert the reception of a group of event. To be able
to know the attended event count it is better to define it directly when you
pass the table of event group. The event name as the key and the number
of event that you are waiting for. Also returning the total of received events
instead of 1 then it could be asserted to the expected total count.
Fix: segfault when manipulating data history values:
There was a segfault and random unexpected behavior when attempting
to access old event's data. Only the last one was available and trying
to access older values lead to memory access violation as the JSON
representing the old data has been released since. So it completely
mess up the memory and causes unexpected situations.
This is simply fix by deep copying the data into another memory space
which could be safely accessed afterwards.
Changes the way to receive events from monitor api:
The old method isn't accurate because it tolds monitor
to trace all api request and all push_after event from that
api. But we only want event from the api not the others messages
coming from the binder which aren't event.
Change-Id: Id5aa4a0c79d2adba050ef03d58c45a3db72ec2a2
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Processing both event coming from the wanted api and from
monitor (which gave the same event but with more informations)
leads to unexpected behavior since you can't know which event's
data has been registered so data structure changes and can't be
asserted.
Change-Id: Ifb32c9fdb3b6cc061d0fe5e8d1e5481d51e8d886
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Fix: No events defined in the mock apis
Fix: new_api function has changed in binder
Using the dynapi new_api function returned 0 in case of success
and -1 on failure. New function since v3 returned NULL in case of
failure or the api struct in case of success.
Fix: wrong install_prefix variable used in CMake config file
Fix: wrong variable used
Typo after a copy/paste from event group handling.
- Wrong use of table.insert
- Wrong variable name used
- only pass the data table, which is embed in another data
table...
- Fix aftereach and beforeeach function's call
Change-Id: I9523ae50c170a3cdb9e5c3bc2b9e923c30f6ba39
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Change-Id: Ia067ce46f13bc49b6050522d0484f92627968ff1
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|
|
Now you could load supplementary tests api by providing either a path
to a JSON configuration file or directly a JSON object representing a
test configuration.
Change-Id: I3145c28aaea482b934e9f9fed6f2969e32da5901
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
|