summaryrefslogtreecommitdiffstats
path: root/CAN-binder/libs/openxc-message-format/openxc.proto
diff options
context:
space:
mode:
authorRomain Forlot <romain.forlot@iot.bzh>2017-06-20 10:24:05 +0000
committerRomain Forlot <romain.forlot@iot.bzh>2017-06-20 10:24:05 +0000
commit32e25cbca210a359b09768537b6f443fe90a3070 (patch)
tree3309794c15d8a8f8e9c1c08cad072ee1378813ba /CAN-binder/libs/openxc-message-format/openxc.proto
parent76c43dec62b2e21cd6446360c00d4fe6b437533f (diff)
Separation Generator to a dedicated repo
Change-Id: Id94831651c3266861435272a6e36c7884bef2c45 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
Diffstat (limited to 'CAN-binder/libs/openxc-message-format/openxc.proto')
-rw-r--r--CAN-binder/libs/openxc-message-format/openxc.proto174
1 files changed, 0 insertions, 174 deletions
diff --git a/CAN-binder/libs/openxc-message-format/openxc.proto b/CAN-binder/libs/openxc-message-format/openxc.proto
deleted file mode 100644
index db7164f..0000000
--- a/CAN-binder/libs/openxc-message-format/openxc.proto
+++ /dev/null
@@ -1,174 +0,0 @@
-package openxc;
-
-option java_package = "com.openxc";
-option java_outer_classname = "BinaryMessages";
-
-message VehicleMessage {
- enum Type { CAN = 1; SIMPLE = 2; DIAGNOSTIC = 3; CONTROL_COMMAND = 4;
- COMMAND_RESPONSE = 5; }
-
- optional Type type = 1;
- optional CanMessage can_message = 2;
- optional SimpleMessage simple_message = 3;
- optional DiagnosticResponse diagnostic_response = 4;
- optional ControlCommand control_command = 5;
- optional CommandResponse command_response = 6;
- optional uint64 timestamp = 7;
-}
-
-message CanMessage {
- enum FrameFormat {
- STANDARD = 1;
- EXTENDED = 2;
- }
- optional int32 bus = 1;
- optional uint32 id = 2;
- optional bytes data = 3;
- optional FrameFormat frame_format = 4;
-}
-
-message ControlCommand {
- enum Type {
- VERSION = 1;
- DEVICE_ID = 2;
- DIAGNOSTIC = 3;
- PASSTHROUGH = 4;
- ACCEPTANCE_FILTER_BYPASS = 5;
- PAYLOAD_FORMAT = 6;
- PREDEFINED_OBD2_REQUESTS = 7;
- MODEM_CONFIGURATION = 8;
- RTC_CONFIGURATION = 9;
- SD_MOUNT_STATUS = 10;
- PLATFORM = 11;
- }
-
- optional Type type = 1;
- optional DiagnosticControlCommand diagnostic_request = 2;
- optional PassthroughModeControlCommand passthrough_mode_request = 3;
- optional AcceptanceFilterBypassCommand acceptance_filter_bypass_command = 4;
- optional PayloadFormatCommand payload_format_command = 5;
- optional PredefinedObd2RequestsCommand predefined_obd2_requests_command = 6;
- optional ModemConfigurationCommand modem_configuration_command = 7;
- optional RTCConfigurationCommand rtc_configuration_command = 8;
-}
-
-message DiagnosticControlCommand {
- enum Action { ADD = 1; CANCEL = 2; }
-
- optional DiagnosticRequest request = 1;
- optional Action action = 2;
-}
-
-message PassthroughModeControlCommand {
- optional int32 bus = 1;
- optional bool enabled = 2;
-}
-
-message AcceptanceFilterBypassCommand {
- optional int32 bus = 1;
- optional bool bypass = 2;
-}
-
-message PayloadFormatCommand {
- enum PayloadFormat {
- JSON = 1;
- PROTOBUF = 2;
- MESSAGEPACK = 3;
- }
-
- optional PayloadFormat format = 1;
-}
-
-message PredefinedObd2RequestsCommand {
- optional bool enabled = 1;
-}
-
-message NetworkOperatorSettings {
- enum OperatorSelectMode {
- AUTOMATIC = 0;
- MANUAL = 1;
- DEREGISTER = 2;
- SET_ONLY = 3;
- MANUAL_AUTOMATIC = 4;
- }
- message NetworkDescriptor {
- enum NetworkType {
- GSM = 0;
- UTRAN = 2;
- }
- optional uint32 PLMN = 1;
- optional NetworkType networkType = 2;
- }
- optional bool allowDataRoaming = 1;
- optional OperatorSelectMode operatorSelectMode = 2;
- optional NetworkDescriptor networkDescriptor = 3;
-}
-
-message NetworkDataSettings {
- optional string APN = 1;
-}
-
-message ServerConnectSettings {
- optional string host = 1;
- optional uint32 port = 2;
-}
-
-message ModemConfigurationCommand {
- optional NetworkOperatorSettings networkOperatorSettings = 1;
- optional NetworkDataSettings networkDataSettings = 2;
- optional ServerConnectSettings serverConnectSettings = 3;
-}
-
-message RTCConfigurationCommand {
- optional uint32 unix_time = 1;
-}
-
-message CommandResponse {
- optional ControlCommand.Type type = 1;
- optional string message = 2;
- optional bool status = 3;
-}
-
-message DiagnosticRequest {
- enum DecodedType { NONE = 1; OBD2 = 2; }
-
- optional int32 bus = 1;
- optional uint32 message_id = 2;
- optional uint32 mode = 3;
- optional uint32 pid = 4;
- // TODO we are capping this at 8 bytes for now - need to change when we
- // support multi-frame responses
- optional bytes payload = 5;
- optional bool multiple_responses = 6;
- optional double frequency = 7;
- optional string name = 8;
- optional DecodedType decoded_type = 9;
-}
-
-message DiagnosticResponse {
- optional int32 bus = 1;
- optional uint32 message_id = 2;
- optional uint32 mode = 3;
- optional uint32 pid = 4;
- optional bool success = 5;
- optional uint32 negative_response_code = 6;
- // TODO we are capping this at 8 bytes for now - need to change when we
- // support multi-frame responses
- optional bytes payload = 7;
- optional double value = 8;
-}
-
-message DynamicField {
- enum Type { STRING = 1; NUM = 2; BOOL = 3; }
-
- optional Type type = 1;
- optional string string_value = 2;
- optional double numeric_value = 3;
- optional bool boolean_value = 4;
-}
-
-message SimpleMessage {
- optional string name = 1;
- optional DynamicField value = 2;
- optional DynamicField event = 3;
-}