summaryrefslogtreecommitdiffstats
AgeCommit message (Collapse)AuthorFilesLines
2017-03-20Use gitbook to manage documentationSebastien Douheret26-357/+1000
Signed-off-by: Sebastien Douheret <sebastien.douheret@iot.bzh>
2017-03-20Update toyota exampleRomain Forlot2-22/+22
Change-Id: Ied4f715b486a2d4ef2b5ba4d49bbc339f95bffad Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-20Spellchecking and typoRomain Forlot1-18/+26
Change-Id: I1f1c2cbc68e3c25d827657e2d08822e45a59d275 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-20Make error goes back to the subscribed clients when unsupported.Romain Forlot2-1/+1
Change-Id: Ic864803c8dffdab3cc9bf5bf281ce032600a732f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-20Fix: Avoid segfault if diagnostic bus isn't correctly set.Romain Forlot3-10/+24
There is a segfault when binding configuration doesn't matches configuration generated. Improve general CAN bus device initialization. Change-Id: I17ea94ee54841d09ac63a7ffad303a88d99e0173 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-19Fix bad handling unsupported OBD2 messages subscription.Romain Forlot2-3/+4
Testing supported boolean wrong and gave a null pointer to a function that doesn't check the pointer validity. Change-Id: I49e88a68f266546dbd257b0fdade860cead1322d Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-18Improve Toyota examples.Romain Forlot4-130/+142
Generate a new version of the configuration generated for Toyota Auris 2010. Remove the one from src directory. It has to be paste prior to build the binding once generated. Change-Id: I0b8e5415df0d0fade70dfa193ad45770c6db38dd Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-17added toyota's exemple.Loïc Collignon2-0/+451
Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>
2017-03-17Typo and formating and rework somes sentences.Romain Forlot4-14/+49
Change-Id: If222728bfc9120065fd56f0877d3736634f6fc52 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-17Comments fixes, typo and formating.Romain Forlot21-603/+575
No more warning when generate the docs and all comments follow the same formating. Change-Id: I80d4c5c2d64401c2e53a550c60155680c4f968ce Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-17moved exemples files.Loïc Collignon3-0/+0
Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>
2017-03-17Convert svg to png for the docRomain Forlot7-1111/+3
Change-Id: Ia62cba8da3db425d63c18104d597cd577f9651ab Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-17Adding some abstract to the READme.Romain Forlot4-1/+1132
Present the CAN binding architecture. Change-Id: I7ab2a96e468a57e882a2eca93aedaacdc057794b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-17Improve READme instructions.Romain Forlot1-18/+191
Change-Id: I8b507d3e34ed3d34680e6e15b7f97b7e17fc1c4f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Diagnostic requests will occur depending on their frequency.Romain Forlot1-1/+1
Hardcoded offset was for testing purpose, now we can use frequency offset. Change-Id: I920e61cd8f587ead9c77aec158edb4dee28b927d Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Wrong error handling when fire diagnostic request.Romain Forlot1-6/+4
As returned code was negative value the sd_event_source stopped considering that was an error. If statement was to check that sd_event_set_enabled was ok, so unref and return wasn't at the right location... Change-Id: I91cc943c20af80a31b4f66f5714ccef93c0fdbd2 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Generate a configuration example with diagnostic messages filled too.Romain Forlot1-120/+36
It was filled by hand for the moment. Change-Id: Ie72cd670bbc9c7a568507290f4bb25019ec58098 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: decoded name will be prefixed as at subscription.Romain Forlot1-1/+1
Reason is that the simple message is used to match a subscribed signals in the map. So it has to be the same that at the subscription. Change-Id: Ie9504583948027523a7288b5e4a20707c49b6d59 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Doxygen base configuration file and logo.Romain Forlot2-0/+2548
Change-Id: If1fbbefa386e1e72121ff28fce6f55569129272c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16gitignore updateRomain Forlot1-0/+1
Change-Id: I97af1fab19d7d071e7c34d4149ae67442f257690 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Include cleaningRomain Forlot15-23/+19
Change-Id: I5df96540400b833e684001f8fc5fa33ff1892bae Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Adding missing doxygen comments.Romain Forlot12-162/+332
Made some cleaning about unused things or obsolete. Review existing comments, adding missing comments. Reformat some long long constructor. Change-Id: Ibae247d1295a7a85b49d0ecee473022755d42b8b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Generated cpp file example.Romain Forlot1-60/+163
Change-Id: I1608db0120a0501af0e4327fe348ef149d90bad4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Use index number between objects to set their links.Romain Forlot6-22/+75
Needed to use generator. Change-Id: I82b44fa1e53c55e2cd90ae7017906a22b7f0636e Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>
2017-03-16added a folder to ignore in .gitignore.Loïc Collignon1-0/+1
Signed-off-by: Loïc Collignon <loic.collignon@iot.bzh>
2017-03-16Implement check of supported diagnostic PID.Romain Forlot5-3/+31
Supported boolean member about diagnostic messages is now used. When a response is received, completed but not successful, then set the diagnostic message as not supported and clean the request from the queue. Subscription remains for now, not cool but will be fix soon. Change-Id: Ia5dc78d4a770f80f144724f4df6eabd2ffd4b8cc Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve commentsRomain Forlot2-2/+3
Change-Id: I1e43b0aeaff738db11695e77fee23e8c9809f0c1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Make unsubscription works with diagnostic message too.Romain Forlot1-11/+20
Now unsubscription really make unsubscription and stop polling diagnostic request. Change-Id: I31830c7af97506e1231fb5f1244c350520a2df29 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix commentsRomain Forlot1-2/+1
Change-Id: Ia838d06885bc95196c5afc3668c0b028cb0f2763 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix diagnostic message name mismatch at decoding.Romain Forlot1-1/+1
Retrieve adr name prefixed will add uneeded prefix as it is already present. At build time of a Diagnostic request from a diagnostic message, this prefix is added so adr name is already correct. *adr: active diagnostic request Change-Id: Ie5c364bf47a28c80290021651941cd37fa26321a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Follow rename operation in CMakeLists.txtRomain Forlot9-9/+9
Rename has been made with filter-branch using utility git-mv-with-history, so file history follow the rename operation. This is a commit to fix include and CMake file. Change-Id: I8542c7def3143854a2008fa069dd3232f2497394 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Small fixesRomain Forlot2-4/+3
Align frequency type to float and removed useless code. Change-Id: I13d9407808c42ece0d3fd761351752ad661e01e0 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Finalization of decoding part of diagnostic messages.Romain Forlot4-67/+102
Diagnostic request must have a name to be subscribed. Else, we can't decode or event push for now. Change-Id: I0901a71da31320d8598e512614437aceb552713d Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Retrieve easily Diagnostic Request PID from an Active Diagnostic RequestRomain Forlot2-0/+10
Change-Id: I787cd94b338c458fda0259bd2bcf47a1fa85cc3f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Ease use of openXC structures.Romain Forlot2-0/+29
Add some helpers functions used to check VehicleMessage validity or build default VehicleMessage struct. Change-Id: Ia1cca8b4cb3dd70a739d0f2ee9165b72fdac48d4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Rename class and 1:1 map to JSON description fileRomain Forlot7-55/+73
Added decoder and callback member that will be set by generator and taken at submission to be used later, storing them into an active diagnostic request instance, when response CAN message comes in. Change-Id: I9ded05de3bb28ec55e4e007d72d0e1924141a6a6 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Make available decoding OBD2 messages method to be use as callback.Romain Forlot4-19/+22
Change the method to static 'cause it will be call from outside of the class. Change-Id: I88dcd845559fac7892cd489cd6e8198c143ee2a8 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Simplification of checking Diagnostic response.Romain Forlot3-26/+17
A CAN message will be considered as a Diagnostic response when its arbitration ID is between standardized 0x7E8 and 0x7EF. Checking which request belong to that response will done in later methods Change-Id: I7a093edf44b62a4552b90fe3d8935f94dc677cf4 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve memory allocation about Signal states.Romain Forlot4-12/+12
Returning to Signal states map avoiding hole in vector allocation as we did not know how many state a Signal can takes. So a map may be a better choice Will see. Change-Id: Ie3ccdbd31296c5c0ebaefc109e75f2e0cde03756 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Revert accessing CAN device with a map indexing on dev nameRomain Forlot13-42/+73
Main reason for that behavior revert is because of generator that rely on CAN device name and so we have point on these object by specify the device name. Instead of shared pointer between objects, instead binding is based on device name. With a device name you can get the shared pointer on it using new static method from can_bus_t object. Change-Id: I331e0ad8d03c88a15c697d12a9fce3699b0cd962 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Uniformization between get_name() method of signals.Romain Forlot1-2/+2
can_signal_t and active_diagnostic_message return name with prefix using this method. If you need without it then use get_generic_name. Change-Id: I6b153eb20214049c10619d39fcc65c8641a9e32f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Littles comments improvmentsRomain Forlot1-2/+2
Change-Id: Idcc7e5b4dedad8e39eb829b25502d7dea3e5b29a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Change way to check prefix of signals name.Romain Forlot2-2/+5
Change-Id: I9a0726ab41c4801e7a5305731ce78ddd03aff9e1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Improve shims_logger function to get full details.Romain Forlot1-3/+8
Change-Id: I752db65cb3fbca4d33b932f3a0c597adfaf79903 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Get recurring requests works.Romain Forlot1-38/+33
Implements event_loop logic. Change-Id: Ia5ac32820a0421bbcb69d8b0dd3bea2b7b582444 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Simplification of diagnostic manager. Delete uneeded vectorRomain Forlot2-51/+22
Control size manually, don't rely on STL container. Change-Id: Iede2f9b233c5b8a6dc77c9b146ffc92da8e7a989 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Return period without unit conversion.Romain Forlot1-3/+1
If conversion must be made then make it at the call not upstream. Change-Id: Ief6dee40355c7b39b5e27d0ba3dc02717fadf43b Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Search signals against name not generic_name. It's madeRomain Forlot2-3/+3
to get able to get difference between classic CAN messages and diagnostic messages based on name signals prefix. Change-Id: I696facc58f38150e0457d519dcabffba750a8db3 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Less control before process the CAN message.Romain Forlot1-6/+5
Change-Id: I341d29d217b2a92652e9985d8c93829e0211bddc Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Implement regular event launching using systemd event loopRomain Forlot3-21/+49
Regular events is made launch a timerfd event from binder event loop and then in the event handler, reschedule next launch in the future based upon the signal frequency. Change-Id: I0b1e84eb2135474f4bcc5ee256ba513eea4035a6 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>