summaryrefslogtreecommitdiffstats
path: root/src/diagnostic/diagnostic-message.cpp
AgeCommit message (Collapse)AuthorFilesLines
2017-03-16Move member from obd2_signals_t class toRomain Forlot1-70/+2
active_diagnostic_request_t (adr)class. It's more logical to have them here as call about incoming diagnostic CAN messages are made against adr class not obd2_signal_t that it's a subset of diagnostic messages. It's made to handle obd2 requests as well as normal UDS diagnostic request for constructor proprietary diagnostic signals. Change-Id: I96c714640d6ecfa25dfc9942974057c1797eb0e1 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Change the way to check signal type making prefix_Romain Forlot1-4/+6
attribute as static with a static class method which will check that the beginning of string argument matches the prefix. Change-Id: Idb129c7179391da61447996560957b2791aa9383 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Reordering class method.Romain Forlot1-17/+17
Change-Id: I61cca1117a987280383538a0b0e307429bee4fc3 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Implemente way to send diagnostic request when subscribed.Romain Forlot1-0/+5
When subscribed, the signal is added to recurring request list of diagnostic manager and an event is added to the systemd event loop with timer set using frequency parameter from the requested signal. Change-Id: I4d604c498047d7744c090b7f03fce0f2b427fd01 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16We doesn't modify member once getted, we can use const returnRomain Forlot1-6/+21
and const method. Change-Id: I0f7465af74b1c9a546af45a0d1eea33c93537e0c Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Manage prefix on CAN and OBD2 prefix. Searching signalsRomain Forlot1-0/+10
is made on generic_name (without prefix) and returned vector of string is filled with name with prefix. Then you can process on them based upon their name differently. OBD2 signals will generated recurring request on diagnostic manager and decoding will not be handled the same way too. Change-Id: I2c5239ef49661941a0a748debe0bd536b2954b3a Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: include statement with wrong path.Romain Forlot1-2/+3
And minor fixes. Change-Id: Ica55c0708edd86d0aa37e7117b3c3fad551a0167 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: include path (where I think to fix them...)Romain Forlot1-2/+3
Change-Id: Ib44693efc9347fc4fdf40a1748725d5191303199 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Move some functions to configuration class.Romain Forlot1-23/+2
Change-Id: I87b1b6961206ae3848cf6aca367698218fe1523e Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix all doxygen comments about parameters.Romain Forlot1-4/+4
Change-Id: Idbe268d07ebf53a63c9543d9cca94ded34a29731 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Added a warning that it is an example codeRomain Forlot1-8/+8
Change-Id: Ib66e49960a348896020fba56f7d98910623af83f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Beginning of work of get central configuration objectRomain Forlot1-37/+0
that will be used by the binding to access generated elements. It will hold generated structure/objects and make a resume to the binding configuration. Idea is to have an object that can be inherited in the generated code to extend its functionnalities or change some of its behoviors. Change-Id: If2ce5cbe2eb98a74a8e3f13000ee02855674216f Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: typo, and dirty fix to get compiled ftm.Romain Forlot1-1/+2
Change-Id: I74042051346a0f0f4de7152e2a668c041edaebde Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Introducing diagnostic manager class.Romain Forlot1-14/+1
It will hold communication through uds-c lib allowing to communication with diagnostic protocol obd2. It is attached to can_bus_dev_t class 'cause it must regularly send CAN message through it. Change-Id: I2d9d8dfaca10e9865bf82b0ae83e65490ca982f8 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Make an extern get_signal_id() function plug to get_pid()Romain Forlot1-2/+12
member function from class obd2_signals class. Change-Id: I5a0f1cfd0c2fb9374cc3928861ca4e8a52911942 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Fix: wrong function signature and get out from classRomain Forlot1-1/+1
temporarly to get compiled project. Change-Id: I7235f503c42a3e31d09094c42882b74e5e809493 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Include file changes, typo and renaming operation.Romain Forlot1-18/+10
Change-Id: I6643333cfcc8bea120496c53f1cd3b8596e33398 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
2017-03-16Beginning of work on obd2 object andRomain Forlot1-0/+206
files reorganization. Change-Id: Idaa7ad05c45d734ce771506fd6e41f1a09a6ac66 Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>