summaryrefslogtreecommitdiffstats
path: root/4a-hal/4a-hal-controllers
AgeCommit message (Collapse)AuthorFilesLines
2018-10-08Correct a syntax mistake in function declarationJonathan Aillet1-1/+1
Correct a syntax mistake in 'HalCtlsNormalizeJsonValues' function declaration. Change-Id: If8f32c9f55a7c8b1075a5b493d467e66d4b2c1f6 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change mixer data structures namesJonathan Aillet1-2/+2
Change mixer data structures names bacause we won't only stores streams data anymore. Change-Id: Id7e4482b6a69696d156c6a8bfc8f8d231dba9d2c Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change name of 'list' verb to 'info'Jonathan Aillet3-3/+3
Change name of 'list' verb to 'info'. Change-Id: I9062344b67cc2c19bce9a34d4ac7abfc1baa9428 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Move controller config exec before onload actionJonathan Aillet1-4/+8
Before, the onload action specified in the audio configuration file (see controller documention) was exectued before the sections configuration execution call. So, the onload action was launched before the hal was ready. Now, onload action is launched last. Change-Id: I05d46622b938ae5a818bd404779a2263ed334397 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Add search for a concurent hal at mixer attachJonathan Aillet1-3/+19
At hal mixer attach, add search for an already ready hal using the same alsa audio device id. If this concurent hal exists, return an error. Change-Id: Ia17738fe87c7bc82fa1867ecd031dd07ffa73714 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Return an error when hal attach to mixer fails.Jonathan Aillet1-1/+3
Return an error when hal is not successfully attach to mixer. Change-Id: Ibfacf405153e87d8005feba17f963b2f49caad7a Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change paramters in functions handling hal dataJonathan Aillet1-1/+1
Change paramters in functions handling hal data structure. Now, the only thing you need to add/search for/remove something in hal data structure list is the address of the first element of the list instead of the address of the whole hal manager data structure. Change-Id: Iafa7428735c3aa418a6ef6564f9acde8f44e7dfe Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Add free of 'CtlHalAlsaMapT' data structureJonathan Aillet2-2/+26
Add free of 'CtlHalAlsaMapT' data structure. Change-Id: Icabc1d6f0d6e6977fead8260dd3932c6004c5d10 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Update request success macro used in codeJonathan Aillet2-4/+4
Update request success macro used in code to correct compilation error. Change-Id: I0cb9c07b27000935b01aaaa17d5656f05d4e21ff Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Move mixer attach at hal startupJonathan Aillet5-94/+112
Move mixer attach at hal startup instead of making attachment possible only with a verb. Now, if the hal audio device is detected at startup, it will automatically be attached to the mixer. As it is useless now, the verb used to attach mixer has been deleted. Change-Id: I32c8b829ac37fb31ede4fe8830a6f2a699c0835c Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Add value normalization of alsa control valuesJonathan Aillet4-18/+236
Add functions that allows to normalize values that are requested to be sent with an alsa set control call (using alsacore). Change-Id: I5046a66d807c9b9b6751e036a47303ceddc0c16a Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Get alsa controls properties at control getJonathan Aillet2-11/+28
Get alsa controls properties by parsing the response sent by balsacore when we search for an existing alsa control. Change-Id: I9d13327ae2ef79c793dbd227589740f7e336e46c Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Process and handle alsa controls mapJonathan Aillet5-6/+719
Process and handle alsa controls map by : Parse and store info from 'halmap' section into a structure. If the hal is available : - Test if controls are available (if use of existing control). - Create new controls (if use of control to create). - Add a verb for each element of the section. - Handle call to alsa when a verb request is detected. - Resgister to event from this device. - Handle call to action if event on this control is detected. Change-Id: I246e16e9d02e64a1778f5c78d2458a33bdfb6d7e Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Correct a typo in responsesJonathan Aillet1-2/+2
Correct a typo in responses of the callback that transfer action to mixer. Change-Id: Ic9c33c00367963a6a3d3dbdf21b0e4cad27d0f7d Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Remove an unnecessary variableJonathan Aillet1-3/+2
Remove an unnecessary variable because it was used to get the result of a function call and to test this result (in a 'if' statment). So, to remove it, function was put directly into the 'if' statment. Change-Id: Ie79caa35b0873c6ec7cfdb19a25a3506c0082e53 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Prevent sending data to mixer of hal is not readyJonathan Aillet1-2/+2
Prevent sending data to mixer of hal is not ready. Change-Id: Ie511a5e23760e87336745dbe15d8d2a5e9481518 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change the field name use to store card pathJonathan Aillet1-2/+2
Change the field name use to store card path into controller hal data structure. Change-Id: I4413a4e5550f3122055db4c6184907d8be407ceb Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Use a boolean to set if api is internalJonathan Aillet1-1/+1
Use a boolean to set if api is internal. Change-Id: Ife5b8e052cf416205aca73c270bfb4b131be3656 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change the way to get card id using its pathJonathan Aillet3-47/+49
Change the way to get card id using its path by returning directly the found card id. Corrects a typo in alsa core link header. Change-Id: Ib202632e049921a57428b31a29f7def4d9e78aaa Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change a comment about what to listJonathan Aillet1-1/+1
Change a comment about what to provide when list verb is called. Add 'playback' and 'capture' to response. Change-Id: I2b663d9a83b18f870dbd7b23be4ef8f41664e25f Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change some comments to add TBD thingsJonathan Aillet1-2/+2
- Change some comments from TODO to TDB. - Remove 'JAI' from warning messages. Change-Id: Ib2c39d4e0f0ca34929237ab8ca3d66c9c0d269d0 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Include afb-definitions when using application frameworkJonathan Aillet8-86/+86
Include <afb-definitions.h> from 'app-controller' instead of <afb/afb-binding.h> and use its definitions. It allows to migrate from an application framework version to another with less impact on the code. Change-Id: I22359cd3fe22145b3d6c551f227be2ba7e1b65d5 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Correct a debug warning about a variableJonathan Aillet1-1/+1
Correct a debug warning about a uninitialized variable. Change-Id: I94b8a5ba42013dd0ede5706a1646a61d58e7ef73 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Fix a typo in a debug messageJonathan Aillet1-5/+5
Fix a typo in a debug message. Change-Id: Iee894287f43d74fd72e41faad42f0617c50c0cf8 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Handle hal status using card presence and mixer initJonathan Aillet4-5/+134
Test audio card presence at hal startup using alsacore call. Handling a new state of hal. Move alsacore link files into 4a-hal-controllers. Check state of hal before mixer initialization call. Actualize hal state if mixer initlialization ends well. Add a sndCardId filed to 'SpecificHalData' structure which will contain audio card if (from alsa). Change-Id: I2e82a14ee6ba6e63f06fe2b498587783941b7b98 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Generate an error when mixer initialization failsJonathan Aillet1-6/+6
Generate an error when mixer initialization is correctly transfered to mixer api but an error was raised by it. Change-Id: I617686b0167f9fb536ec56e430d10560e7f7ca31 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Use error codes when handling mixer init responseJonathan Aillet2-6/+16
Use error codes when handling mixer initialization response. Change-Id: Ie62b022f1a653be18766a09f1803995a77ae8582 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Replace controller macro use by app fw macro useJonathan Aillet2-8/+9
Replace controller macro use by application framework macro use. Change-Id: Icee0855a311857ab21a4a5031c4e06ac58b8f295 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Add some missing castJonathan Aillet1-3/+3
Add some missing cast when getting controller hal data structure. Change-Id: I8fdfd7486345e89c4004c071b63890b751305ce2 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Handle app fw call errors in a dedicated functionJonathan Aillet3-71/+4
Two functions has been added in a new file in 4a-hal-utilities : - A function that handle application framework call errors by returning a specific error. - A function that handle application framework call errors from a request. Change-Id: I657773586111adc609cbbaead7db589a82e133b0 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Rename a filed of 'CtlHalStreamData' structureJonathan Aillet2-2/+2
Rename 'cardId' filed to 'streamCardId' in 'CtlHalStreamData' structure. Change-Id: I7615eece39aea6bf6b6aadd3361f58792e6531f6 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Correct date in .c and .h filesJonathan Aillet6-6/+6
Set file creation date to 2018 instead of 2016. Change-Id: I0349bbc1dde097f899d9b38dd28b3891f88020ad Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Correction of list verb when there's no streamsJonathan Aillet1-1/+1
Don't raise an error when list verb is called on a controller hal and there's no streams registered yet. Change-Id: Ie4126673f134ced3e93e1111f988923e4bf13e64 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Fix typo in request reponses of a app fw verbJonathan Aillet1-2/+2
Fix typo in request answers info message send back to application framework after an api verb call. Change-Id: Icbd06fc13d9abff8325145c355b6c8c3c6434e1c Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Handle mixer responses correctlyJonathan Aillet3-14/+75
Use a function to handle mixer responses on stream action calls correctly. Before, there was no differencations between responses from api calls that didn't end well. Now, we print a different message if the api/verb is not found and if the request was transfered but an error occured during it. Change-Id: Ib4f9c3cf14b6612cd14762b74466ce484fdfb09d Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Handle mixer response after its initJonathan Aillet4-56/+148
Handle mixer response to get created streams and them corresponding card ids after mixer initialization. Store these informations into the controller hal data strucure. Creation of a verb for each stream is now handle at response handling. Remove unnecessary function because we don't need to search for a stream by his name. Change-Id: Id9e598668b071ca18d152b57e71109314025f698 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Don't seal hal controller api at its initJonathan Aillet1-2/+0
To be able to declare new verbs for controller hal dynamic api, don't seal this api after its initialization. Change-Id: I0fd028034ef2f409eceae05b642c74163b26e332 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Store uid of the hal mixer configuration and use itJonathan Aillet2-11/+17
Stores uid of the hal mixer configuration in the specific controller hal structure. Use this uid as prefix when calling softmixer api. Change-Id: Iab00518e02e0f9ff6dbd78c126eda45225c55256 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Implementation of 'list' verb for controller halJonathan Aillet1-3/+58
Implementation of function allowing to list streams and controls of a controller hal. Change-Id: Ic347dd89dbbf36056b0fc3c5fe25bd111a85f627 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Parse config to get streams 'halmap' controlsJonathan Aillet3-3/+9
Parse controller config to get 'halmap' controls, these controls are inside 'halmap' section of controller configuration file. Change-Id: I71fb8494927cf05d9751a69fede4b7622921c6c2 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Handle stream calls to transfer to mixer apiJonathan Aillet2-3/+70
Implementation of the function that transfer hal streams calls to mixer api. Change-Id: Icded7e160a1cfbe794c5fa2695bf0f9f54c80a06 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Add 'init-mixer' verb to hal controllerJonathan Aillet3-1/+64
Add creation of 4a-softmixer mixer as hal controller verb called 'init-mixer'. This verb sends json mixer configration to mixer api. Add a forgotten cast. Change-Id: Id4ca6b68caf21c74fb6b17b953d8db2f2db0c04b Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Parse controller config to get halmixer json objectJonathan Aillet3-1/+105
Parse controller configuration to get halmixer json object, this object is inside 'halmixer' section of controller configuration file. Use streams defined in this 'halmixer' section to get available streams of this hal, store them, and declare them as hal api verbs. Change-Id: I47adb2756f89f2a84c8d651ba38ecea5b84079c3 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Use a structure to store ctl hal specific dataJonathan Aillet1-3/+8
To avoid multiple variables at NULL in specific hal data, use a structure to store all controller hal specific data. These data won't be use if the hal is external (registered). Example of controller hal specific data : - Mixer api name - Mixer initialization json - Mixer streams names and card id ... Change-Id: Ifc4823d5ea21ed408b4ecc25b870cad74d3b2173 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Rename function used to load verbs into a dynamic apiJonathan Aillet1-1/+1
Rename function used to load verbs into a dynamic api from 'HalUtlLoadStaticVerbs' to 'HalUtlLoadVerbs' because it is used to load not only static verbs. Change-Id: Idc033ccf0a8e7556e0809e8fa3554d09d0e81d39 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Remove the 'ping' of each hal controller apiJonathan Aillet1-2/+0
Remove the 'ping' verb of each hal controller api which won't be useful anymore. Rename action in configuration file to be able ping an api nevertheless. Change-Id: I5b1ce8f8cd83dc3e689c3bd676244477921ba20d Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Add a 'List' verb to each hal controller apiJonathan Aillet3-0/+68
Add a 'List' verb to each hal controller api which will list verbs available for this api. The callback of the verb is not implemented yet. Change-Id: Ibc44ef8673267b0b952b32fb256214452aa3c000 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change the name of controller configuration filesJonathan Aillet1-2/+2
Change the name of controller configuration files to be sure that they will be found during 'CtlConfigScan'. Add the name that the binder should take into config.cmake to be sure that the controller configuration files will be found during 'CtlConfigScan'. Change-Id: I94c55c186c52f6f89b06400133cfbce36221d245 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Remove sections id in sections callbacks structureJonathan Aillet1-6/+5
Remove sections id in sections callbacks structure because it's not mandatory anymore (it's even harder to add a section with these ids). Change-Id: I04caa1c83137e4165c023207d2b58376c176c248 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>
2018-10-08Change names of some structures fieldsJonathan Aillet1-1/+1
Change names of some structures fields to match the fileds name in controller structure. Change-Id: I579ec53835daa010154982539d09d5a2dcbd28b2 Signed-off-by: Jonathan Aillet <jonathan.aillet@iot.bzh>