The use of nanosleep in the previous job wait change fails to build
for me when building af-main-native, so add the required #include of
time.h. It's not clear to me right off why it actually built for the
target without it, that behavior difference may warrant some further
investigation.
Bug-AGL: SPEC-3365, SPEC-3427, SPEC-3457
Signed-off-by: Scott Murray <scott.murray@konsulko.com>
Change-Id: I73203e564c96d3eaea250ce8867149f6a155ec07
|
|
The systemd job to start an application unit may remain queued long
enough after a call into the systemd D-Bus API that the subsequent
state check sees the unit as still inactive. This results in the
application start being incorrectly reported as having failed, when
it will still actually proceed once the job is dequeued and run in
systemd.
To fix this, checking of the state of the job object returned by the
start D-Bus calls has been added in the various wrapper functions in
src/utils-systemd.c. The timeout mechanism used in the new job_wait
helper function is based on the existing state checking logic of the
wait_state_stable function in src/afm-urun.c.
Bug-AGL: SPEC-3365, SPEC-3427, SPEC-3457
Signed-off-by: Scott Murray <scott.murray@konsulko.com>
Change-Id: I01077a4213944233506518869c3dc604bd40f693
|
|
A better handling of systemd state is need to treat
correctly transient states. That change includes:
- Management of states with numeric identifiers
instead of names
- Handling of the state "inactive" as a stable
state. Most of previous seen problems were coming
from that miss.
- Returning no error but also no info on the process
if it falled to "inactive" meaning that it stopped
quickly.
Bug-AGL: SPEC-3323
Change-Id: Ibf35eb6257c5583596d675cad0bec2869f5fd5f7
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Change-Id: I1d68e07563d9f0f139d1bc8128e09a5da0a648af
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Change-Id: Ie2ff321f78c59913373e2ffb2820297fd423d6f4
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Change-Id: Ia4ef2a6e3c07616ccd756933a82f0806844c4faf
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Change-Id: I3855854407ad47c2b9a2288b8425513de5ae94d3
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Change-Id: I8035c10e8f769b7912046b432d43f97297c039b2
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
When installing or deinstalling, it is needed to
issue a "systemctl (--user) restart sockets.target"
This patch implement it on user side.
To be improved.
Change-Id: I152eb6a1cf5df50b1fe3143837d6d42ee6619349
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
This implementation is very basic and
must be improved.
Change-Id: Id1540e646c83285c61849092bbd8fb645c0954ed
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
This fixes a problem with bitbake when building
native packages.
Change-Id: I28586720010237db578ec55cb5254212c88240e7
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
This enumeration is based on the filesystem,
units are listed from the configured directory.
This is necessarily because not all units can be
loaded by systemd but all can be started.
Change-Id: Ic4d1331c8c54f5bbaa747ff8084da2b0c5a65c55
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Opening one connection per part of the
program doesn't make sense and waste resources.
Using a common one is much better.
Change-Id: I74dc3cd7ae41d7bfa2f03f4a252495e8f5f81578
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
The current implementation enforce the reload
when a 'wants' target is created or deleted.
This should work well for system units.
However, for system units, this behaviour isn't
enought when more that a user is active because
only the user that installs the application will
be updated. For this reason, a paralelle mechanism
has to be defined.
Also note that systemd is henceforth required for
tools because wgtpkg-installer needs it now.
Change-Id: I4fc03a44dbc58c2374ea21dbf6b436f646d04e00
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|
|
Isolate the interface to systemd.
Change-Id: I03ea654da9fab2df0e6eec980b0e5623487d1b73
Signed-off-by: José Bollo <jose.bollo@iot.bzh>
|