diff options
author | Manuel Bachmann <manuel.bachmann@iot.bzh> | 2016-06-10 14:08:06 +0200 |
---|---|---|
committer | Yannick Gicquel <yannick.gicquel@iot.bzh> | 2016-10-11 17:09:06 +0200 |
commit | f8bc0b1decdd464e62e2a1497e3287ead96f40d0 (patch) | |
tree | 619f79c269a3f61d97e81af618bd4abb6694f1a6 | |
parent | 6c2aef81c4182695487fabbd19c5c0a84409b49f (diff) |
Fix invalid sink input treatment after module-loopback
When loading module-loopback, it may create a new sink
input replicating the original one, but with no client
attached. We don't want to re-pass this one through the
whole logic (with NULL sink, etc), so just consider it
legit.
Change-Id: I218c459e1685621c1f59e1d8722e0f1cff88d225
Signed-off-by: Manuel Bachmann <manuel.bachmann@iot.bzh>
-rw-r--r-- | discover.c | 4 |
1 files changed, 4 insertions, 0 deletions
@@ -586,6 +586,10 @@ bool pa_discover_preroute_sink_input(struct userdata *u, pa_sink_input_new_data pa_assert_se (nodeset = u->nodeset); pa_assert_se (pl = data->proplist); + /* is this a valid sink input ? */ + if (!data->client) + return true; + /* is there an existing matching node ? */ node = agl_node_get_from_data (u, agl_input, data); |