Age | Commit message (Collapse) | Author | Files | Lines |
|
Add CONFIG_CAN_MCBA_USB to allow usage of Microchip CANbus analyzers
Change-Id: I86d5726150373cb14630a95c7767fd13dd5d0924
Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com>
|
|
This config fragment for CAN bus had both an option for enabling as a
module:
CONFIG_CAN_C_CAN=m
and for disabling:
# CONFIG_CAN_C_CAN is not set
Since the disable came last, disable wins. This caused the C_CAN
driver and the C_CAN_PLATFORM driver (used by the TI dra7-evm) to be
disabled in the kernel.
To fix, remove the option to disable.
Change-Id: I5be0cee161318cdfe7deb9c5e9c9f15d79cda7ac
Fixes: d870883e7b29d212dc3e2a0e6158d837d4356c6a
Signed-off-by: Kevin Hilman <khilman@baylibre.com>
|
|
Add the C_CAN and the C_CAN_PLATFORM modules to be built as a kernel modules,
those modules supports the Bosch D_CAN and C_CAN peripheral IPs
Change-Id: If5657ba12bb5fc5c2ad1e06554a89255fddd4745
Signed-off-by: Khouloud Touil <ktouil@baylibre.com>
|
|
v2 (jsmoeller): Add append files for boards that need special handling.
Change-Id: I172b71be6e825aa6399f22899e9b6eaacc86e72b
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
Signed-off-by: Jan-Simon Möller <jsmoeller@linuxfoundation.org>
Reviewed-on: https://gerrit.automotivelinux.org/gerrit/9791
Tested-by: Jenkins Job builder account <agl-jobbuilder@automotivelinux.org>
ci-image-build: Jenkins Job builder account <agl-jobbuilder@automotivelinux.org>
Reviewed-by: Stéphane Desneux <stephane.desneux@iot.bzh>
|