Age | Commit message (Collapse) | Author | Files | Lines |
|
Add a .link file to set the transmit queue length to 1000 for physical
CAN devices. This matches the default used for vcan devices, and in
testing fixes the transmit buffer overflows when running the simulator
script against an interface.
Bug-AGL: SPEC-4652
Change-Id: Icb190cdcbda9b09e337789d3a88e39f7288f34eb
Signed-off-by: Scott Murray <scott.murray@konsulko.com>
Reviewed-on: https://gerrit.automotivelinux.org/gerrit/c/AGL/meta-agl/+/28291
Tested-by: Jenkins Job builder account
ci-image-build: Jenkins Job builder account
ci-image-boot-test: Jenkins Job builder account
|
|
Add canbus-can-fd.network configuration that can be selected via
CANBUS_NETWORK_CONFIG.
Bug-AGL: SPEC-4633
Change-Id: Ic662be3e991910a4b35e114f144fe399a88ce477
Signed-off-by: Scott Murray <scott.murray@konsulko.com>
Reviewed-on: https://gerrit.automotivelinux.org/gerrit/c/AGL/meta-agl/+/28153
Tested-by: Jenkins Job builder account
ci-image-build: Jenkins Job builder account
ci-image-boot-test: Jenkins Job builder account
|
|
VIRTIO CAN [1] does not support bitrate configuration, it assumes
bitrate configuration is done on backend.
Fixes systemd-networkd failure:
can0: Failed to set CAN interface configurations: Operation not supported
File `canbus-virtio-can.network` is copied from `canbus-can.network`
with `BitRate=` setting removed.
v2: rework patchset to use own systemd-conf-canbus package to
avoid changes in main systemd package.
[1]: https://lists.oasis-open.org/archives/virtio-dev/202208/msg00159.html
Bug-AGL: SPEC-4597
Change-Id: Idb132203501bb99103e76098eea3bb6394b645da
Signed-off-by: Vasyl Vavrychuk <vasyl.vavrychuk@opensynergy.com>
Reviewed-on: https://gerrit.automotivelinux.org/gerrit/c/AGL/meta-agl/+/28104
Tested-by: Jenkins Job builder account
ci-image-build: Jenkins Job builder account
ci-image-boot-test: Jenkins Job builder account
Reviewed-by: Jan-Simon Moeller <jsmoeller@linuxfoundation.org>
|