summaryrefslogtreecommitdiffstats
path: root/meta-pipewire/recipes-multimedia/wireplumber/wireplumber-config-agl/30-alsa-monitor.lua
AgeCommit message (Collapse)AuthorFilesLines
2021-10-14meta-agl: split wireplumber to run in multiple instancesGeorge Kiagiadakis1-151/+0
The "IC SoundManager" design specifies that there needs to be a session manager running in the host to manage devices and permissions, but all the domain-specific policy and app management needs to run in the IVI container, together with the apps. With this split, we are able to achieve that. In addition to the "host" and "policy" instances, we are also adding a "bluetooth" one, which loads the bluetooth plugin and manages the bluetooth device. This can be moved to the IVI container as well, or elsewhere... it only depends on bluez (so it must run in the same container as bluez). For now, given the absence of an IVI container in the lxc-demo image, all instances are running in the host, but it is trivial to move all the non-host ones to another container later. To compliment pipewire-ic-ipc, this change also adds an "alsa-suspend" lua script that runs in the context of the "host" wireplumber instance and its purpose is to mute pipewire-managed alsa devices when there is a sound playing in the IC container (on another alsa device). Finally, this change also adds V4L2 configuration in the "host" wireplumber instance, which is still disabled (and untested), but you can easily enable it for experimentation by uncommenting the relevant line in host.lua.d/90-enable-all.lua Bug-AGL: SPEC-4027 Signed-off-by: George Kiagiadakis <george.kiagiadakis@collabora.com> Change-Id: I9febc4f3919e7c559a5d7d32bfe7bc95c75934f2 Reviewed-on: https://gerrit.automotivelinux.org/gerrit/c/AGL/meta-agl/+/26662 Tested-by: Jenkins Job builder account ci-image-build: Jenkins Job builder account ci-image-boot-test: Jenkins Job builder account Reviewed-by: Naoto YAMAGUCHI <naoto.yamaguchi@aisin.co.jp> Reviewed-by: Jan-Simon Moeller <jsmoeller@linuxfoundation.org>
2021-06-01Remove dra7xx-evm machine supportScott Murray1-10/+0
Remove dra7xx-evm machine template and related BSP configuration tweaks. The configuration is stale and untested, and no one has expressed interest in it for long enough that it seems better to just remove it to avoid confusion about support status. Bug-AGL: SPEC-3934 Signed-off-by: Scott Murray <scott.murray@konsulko.com> Change-Id: I1659eef113cf1e6fcfdddf65f712275b8fc49b6f Reviewed-on: https://gerrit.automotivelinux.org/gerrit/c/AGL/meta-agl/+/26378 Tested-by: Jenkins Job builder account ci-image-build: Jenkins Job builder account ci-image-boot-test: Jenkins Job builder account Reviewed-by: Jan-Simon Moeller <jsmoeller@linuxfoundation.org>
2021-04-26meta-pipewire: update to pipewire 0.3.25 and wireplumber masterGeorge Kiagiadakis1-0/+161
Bug-AGL: SPEC-3844 Change-Id: Ie32bfa43bf078c7d218d3150dc616501b8848bd0 Signed-off-by: George Kiagiadakis <george.kiagiadakis@collabora.com> Reviewed-on: https://gerrit.automotivelinux.org/gerrit/c/AGL/meta-agl/+/26094 Reviewed-by: Jan-Simon Moeller <jsmoeller@linuxfoundation.org> Tested-by: Jan-Simon Moeller <jsmoeller@linuxfoundation.org>