+.. _opal-api-LEDs:
+
+Service Indicators (LEDS)
+=========================
+
+The service indicator is one element of an overall hardware service strategy
+where end user simplicity is a high priority. The goal is system firmware or
+operating system code to isolate hardware failures to the failing FRU and
+automatically activate the fault indicator associated with the failing FRU.
+The end user then needs only to look for the FRU with the active fault
+indicator to know which part to replace.
+
+Different types of indicators handled by LED code:
+
+ - System attention indicator (Check log indicator)
+ Indicates there is a problem with the system that needs attention.
+ - Identify
+ Helps the user locate/identify a particular FRU or resource in the
+ system.
+ - Fault
+ Indicates there is a problem with the FRU or resource at the
+ location with which the indicator is associated.
+
+All LEDs are defined in the device tree (see :ref:`device-tree/ibm,opal/leds`).
+
+LED Design
+----------
+ When it comes to implementation we can classify LEDs into two
+ categories:
+
+1. Hypervisor (OPAL) controlled LEDs (All identify & fault indicators)
+ During boot, we read/cache these LED details in OPAL (location code,
+ state, etc). We use cached data to serve read request from FSP/Host.
+ And we use SPCN passthrough MBOX command to update these LED state.
+
+2. Service processor (FSP) controlled LEDs (System Attention Indicator)
+ During boot, we read/cache this LED info using MBOX command. Later
+ anytime FSP updates this LED, it sends update system parameter
+ notification MBOX command. We use that data to update cached data.
+ LED update request is sent via set/reset attn MBOX command.
+
+LED update request:
+ Both FSP and Host will send LED update requests. We have to serialize
+ SPCN passthrough command. Hence we maintain local queue.
+
+Note:
+
+ - For more information regarding service indicator refer to PAPR spec
+ (Service Indicators chapter).
+
+There are two OPAL calls relating to LED operations.
+
+.. _OPAL_LEDS_GET_INDICATOR:
+
+OPAL_LEDS_GET_INDICATOR
+-----------------------
+
+.. code-block:: c
+
+ #define OPAL_LEDS_GET_INDICATOR 114
+
+ int64_t opal_leds_get_indicator(char *loc_code, u64 *led_mask,
+ u64 *led_value, u64 *max_led_type);
+
+Returns LED state for the given location code.
+
+``loc_code``
+ Location code of the LEDs.
+``led_mask``
+ LED types whose status is available (return by OPAL)
+``led_value``
+ Status of the available LED types (return by OPAL)
+``max_led_type``
+ Maximum number of supported LED types (Host/OPAL)
+
+The host will pass the location code of the LED types (loc_code) and
+maximum number of LED types it understands (max_led_type). OPAL will
+update the 'led_mask' with set bits pointing to LED types whose status
+is available and updates the 'led_value' with actual status. OPAL checks
+the 'max_led_type' to understand whether the host is newer or older
+compared to itself. In the case where the OPAL is newer compared
+to host (OPAL's max_led_type > host's max_led_type), it will update
+led_mask and led_value according to max_led_type requested by the host.
+When the host is newer compared to the OPAL (host's max_led_type >
+OPAL's max_led_type), OPAL updates 'max_led_type' to the maximum
+number of LED type it understands and updates 'led_mask', 'led_value'
+based on that maximum value of LED types.
+
+Currently this is only implemented on FSP basde machines, see
+hw/fsp/fsp-leds.c for more deatails.
+
+.. _OPAL_LEDS_SET_INDICATOR:
+
+OPAL_LEDS_SET_INDICATOR
+-----------------------
+
+.. code-block:: c
+
+ #define OPAL_LEDS_SET_INDICATOR 115
+
+ int64_t opal_leds_set_indicator(uint64_t async_token,
+ char *loc_code, const u64 led_mask,
+ const u64 led_value, u64 *max_led_type);
+
+Sets LED state for the given location code.
+
+``loc_code``
+ Location code of the LEDs to be set.
+``led_mask``
+ LED types whose status will be updated
+``led_value``
+ Requested status of various LED types.
+``max_led_type``
+ Maximum number of supported LED types. If OPAL supports fewer LED types
+ than requested, it will set ``max_led_type`` to the maximum it does support.
+
+The host will pass the location code of the LED types, mask, value
+and maximum number of LED types it understands. OPAL will update
+LED status for all the LED types mentioned in the mask with their
+value mentioned. OPAL checks the 'max_led_type' to understand
+whether the host is newer or older compared to itself. In case where
+the OPAL is newer compared to the host (OPAL's max_led_type >
+host's max_led_type), it updates LED status based on max_led_type
+requested from the host. When the host is newer compared to the OPAL
+(host's max_led_type > OPAL's max_led_type), OPAL updates
+'max_led_type' to the maximum number of LED type it understands and
+then it updates LED status based on that updated maximum value of LED
+types. Host needs to check the returned updated value of max_led_type
+to figure out which part of it's request got served and which ones got
+ignored.
+
+Currently this is only implemented on FSP basde machines, see
+hw/fsp/fsp-leds.c for more deatails.